Development of an unsupervised cycle contrastive unpaired translation network for MRI‐to‐CT synthesis
Authors:
Open Access
- 28 September 2022
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (11) , e13775
Abstract
Purpose: The purpose of this work is to develop and evaluate a novel cycle‐contrastive unpaired translation network (cycleCUT) for synthetic computed tomography (sCT) generation from T1‐weighted magnetic resonance images (MRI).Methods: The cycleCUT proposed in this work integrated the contrastive learning module from contrastive unpaired translation network (CUT) into the cycle‐consistent generative adversarial network (cycleGAN) framework to effectively achieve unsupervised CT synthesis from MRI. The diagnostic MRI and radiotherapy planning CT images of 24 brain cancer patients were obtained and reshuffled to train the network. For comparison, the traditional cycleGAN and CUT were also implemented. The sCT images were then imported into a treatment planning system to verify their feasibility for radiotherapy planning. The mean absolute error (MAE), peak signal‐to‐noise ratio (PSNR), and structural similarity index (SSIM) between the sCT and the corresponding real CT images were calculated. Gamma analysis between sCT‐ and CT‐based dose distributions was also conducted.Results: Quantitative evaluation of an independent test set of six patients showed that the average MAE was 69.62 ± 5.68 Hounsfield Units (HU) for the proposed cycleCUT, significantly (p‐value < 0.05) lower than that for cycleGAN (77.02 ± 6.00 HU) and CUT (78.05 ± 8.29). The average PSNR was 28.73 ± 0.46 decibels (dB) for cycleCUT, significantly larger than that for cycleGAN (27.96 ± 0.49 dB) and CUT (27.95 ± 0.69 dB). The average SSIM for cycleCUT (0.918 ± 0.012) was also significantly higher than that for cycleGAN (0.906 ± 0.012) and CUT (0.903 ± 0.015). Regarding gamma analysis, cycleCUT achieved the highest passing rate (97.95 ± 1.24% at the 2%/2 mm criteria and 10% dose threshold) but was not significantly different from the others.Conclusion: The proposed cycleCUT could be effectively trained using unaligned image data, and could generate better sCT images than cycleGAN and CUT in terms of HU number accuracy and fine structural details.Keywords
This publication has 27 references indexed in Scilit:
- MR-based synthetic CT generation using a deep convolutional neural network methodMedical Physics, 2017
- Dosimetric characterization of MRI‐only treatment planning for brain tumors in atlas‐based pseudo‐CT images generated from standardT1‐weighted MR imagesMedical Physics, 2016
- Feasibility and limitations of bulk density assignment in MRI for head and neck IMRT treatment planningJournal of Applied Clinical Medical Physics, 2014
- MRI-based treatment planning with pseudo CT generated through atlas registrationMedical Physics, 2014
- Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapyPhysics in Medicine & Biology, 2013
- An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Results of a Multi-Institutional Benchmark Test for Cranial CT/MR Image RegistrationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- N4ITK: Improved N3 Bias CorrectionIEEE Transactions on Medical Imaging, 2010
- Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging aloneRadiotherapy and Oncology, 2003
- New variants of a method of MRI scale standardizationIEEE Transactions on Medical Imaging, 2000