Prospective Study of Serration Angioplasty in the Infrapopliteal Arteries Using the Serranator Device: PRELUDE BTK Study
- 20 November 2021
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 29 (4) , 586-593
Abstract
Purpose: The purpose was to evaluate the safety and efficacy of the Serranator percutaneous transluminal angioplasty serration balloon catheter in patients with infrapopliteal peripheral artery disease. Materials and Methods: A prospective, multicenter, single-arm feasibility study in 46 patients with claudication or chronic limb-threatening ischemia, Rutherford Clinical Category (RCC) 3 to 5, that required treatment of the infrapopliteal arteries above the tibiotalar joint. The primary efficacy outcome was device success—successful insertion, balloon inflation and deflation, and removal of the device(s) with a final diameter stenosis of <50%. The primary safety endpoint was a composite of major adverse limb events (MALE) and perioperative death (POD) through 30 day postprocedure. Other outcomes were change in RCC and ankle-brachial index, wound healing, and clinically-driven target lesion revascularization (CD-TLR). A subset of 9 patients were further evaluated by optical coherence tomography (OCT) or intravascular ultrasound (IVUS) for the presence of serrations in treated lesions. Patient follow-up occurred at 30 days and 6 months. Results: Forty-six patients received treatment with the Serranator device and 55 lesions were treated. Fifty-three lesions were deemed analyzable by the core lab with data and reported hereafter. Device success was 91.7% and freedom from MALE + POD through 30 days was 95.7%. Pretreatment stenosis of 82% was reduced to 21.8% and only 1 lesion (1.9%) required a bailout stent for a grade D dissection. The average maximum balloon inflation pressure was 6 atmospheres. Serrations were present in all treated lesions (n=10) in 9 patients imaged with OCT/IVUS as reviewed by the core laboratory. The RCC score improved by 1 or more level in 70% of patients at 6 months with 42% having a score of 0. The 6 month freedom from CD-TLR was 97.7%. Conclusion: Serranator treatment of infrapopliteal lesions showed excellent lumen gain with minimal evidence of arterial injury and low 6 month CD-TLR. Imaging by IVUS and OCT showed serrations without significant dissection, supporting the device’s proposed mechanism of action.Keywords
This publication has 11 references indexed in Scilit:
- PRELUDE Prospective Study of the Serranator Device in the Treatment of Atherosclerotic Lesions in the Superficial Femoral and Popliteal ArteriesJournal of Endovascular Therapy, 2018
- Stellarex Drug-Coated Balloon for Treatment of Femoropopliteal DiseaseCirculation, 2017
- Endovascular Therapy Versus Bypass Surgery as First-Line Treatment Strategies for Critical Limb IschemiaJACC: Cardiovascular Interventions, 2016
- Durability of Treatment Effect Using a Drug-Coated Balloon for Femoropopliteal LesionsJACC, 2015
- Paclitaxel-Coated Balloon in Infrapopliteal ArteriesJACC: Cardiovascular Interventions, 2015
- Trial of a Paclitaxel-Coated Balloon for Femoropopliteal Artery DiseaseThe New England journal of medicine, 2015
- Drug-Eluting Balloon Versus Standard Balloon Angioplasty for Infrapopliteal Arterial Revascularization in Critical Limb IschemiaJACC, 2014
- Drug-Eluting Balloon in Peripheral Intervention for Below the Knee Angioplasty Evaluation (DEBATE-BTK)Circulation, 2013
- Comparison of Orbital Atherectomy Plus Balloon Angioplasty vs. Balloon Angioplasty Alone in Patients With Critical Limb Ischemia: Results of the CALCIUM 360 Randomized Pilot TrialJournal of Endovascular Therapy, 2012
- Use of the Angiosculpt Scoring Balloon for Infrapopliteal Lesions in Patients with Critical Limb Ischemia: 1-Year OutcomeVascular, 2009