Dual energy for pulmonary vein isolation using dual-energy focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 3-month results
Authors:
- Mattias DuytschaeverMDMattias Duytschaever
- Gediminas RačkauskasGRGediminas Račkauskas
- Tom De PotterTPTom De Potter
- Jim HansenJHJim Hansen
- Sebastian KnechtSKSebastian Knecht
- Thomas PhlipsTPThomas Phlips
- Johan VijgenJVJohan Vijgen
- Daniel ScherrDSDaniel Scherr
- Gabor SzeplakiGSGabor Szeplaki
- Hugo Van HerendaelHHHugo Van Herendael
- Mads Brix KronborgMKMads Brix Kronborg
- Benjamin BerteBBBenjamin Berte
Open Access
- 2 May 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (5)
Abstract
Contact force (CF)–sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. ClinicalTrials.gov Identifier: NCT05752487.Keywords
Funding Information
- Biosense Webster, Inc
This publication has 38 references indexed in Scilit:
- Coronary Artery Spasm During Pulsed Field vs Radiofrequency Catheter Ablation of the Mitral IsthmusJAMA Cardiology, 2024
- 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial FibrillationJACC, 2023
- AB-452672-1 EFFECTS OF ELECTRODE CONTACT FORCE ON LESION SIZE PRODUCED BY PULSED FIELD ABLATIONHeart Rhythm, 2023
- Pulsed field ablation in real-world atrial fibrillation patients: clinical recurrence, operator learning curve and re-do procedural findingsJournal of Interventional Cardiac Electrophysiology, 2023
- Ostial dimensional changes after pulmonary vein isolation: Pulsed field ablation vs radiofrequency ablationHeart Rhythm, 2020
- A Lattice-Tip Temperature-Controlled Radiofrequency Ablation CatheterJACC: Clinical Electrophysiology, 2020
- Long-term impact of catheter ablation on arrhythmia burden in low-risk patients with paroxysmal atrial fibrillation: The CLOSE to CURE studyHeart Rhythm, 2020
- The industrialization of ablation: a highly standardized and reproducible workflow for radiofrequency ablation of atrial fibrillationJournal of Interventional Cardiac Electrophysiology, 2019
- Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial FibrillationJACC: Clinical Electrophysiology, 2018
- Incidence of Pulmonary Vein Stenosis After Radiofrequency Catheter Ablation of Atrial FibrillationJACC: Clinical Electrophysiology, 2017