A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy
- 18 August 2015
- journal article
- Published by Wiley in Medical Physics
- Vol. 42 (9) , 5310-5320
Abstract
Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy.Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1‐weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician‐defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation.Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm3 (range, 6.6–44.3 cm3), while the PET segmented GTV was 10.2 cm3 (range, 2.8–45.1 cm3). The median physician‐defined GTV was 22.1 cm3 (range, 4.2–38.4 cm3). The median difference between the multichannel segmented and physician‐defined GTVs was −10.7%, not showing a statistically significant difference (p‐value = 0.43). However, the median difference between the PET segmented and physician‐defined GTVs was −19.2%, showing a statistically significant difference (p‐value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician‐defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively.Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician‐defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.Keywords
Funding Information
- Varian Medical Systems
- National Institutes of Health (P30CA016672)
- National Institutes of Health (NIH) (P30CA016672)
- Varian Medical Systems (Varian Medical Systems, Inc.)
- Varian Medical Systems
- National Institutes of Health (P30CA016672)
This publication has 37 references indexed in Scilit:
- A retrospective, deformable registration analysis of the impact of PET-CT planning on patterns of failure in stereotactic body radiation therapy for recurrent head and neck cancerHead & Neck Oncology, 2012
- An integrated approach to segmentation and nonrigid registration for application in image-guided pelvic radiotherapyMedical Image Analysis, 2011
- Evaluation of Automatic Atlas-Based Lymph Node Segmentation for Head-and-Neck CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- A novel fuzzy C‐means algorithm for unsupervised heterogeneous tumor quantification in PETMedical Physics, 2010
- Tumor delineation: The weakest link in the search for accuracy in radiotherapyJournal of Medical Physics, 2008
- Intraobserver and Interobserver Variability in GTV Delineation on FDG-PET-CT Images of Head and Neck CancersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Simultaneous Truth and Performance Level Estimation (STAPLE): An Algorithm for the Validation of Image SegmentationIEEE Transactions on Medical Imaging, 2004
- A general discrete contour model in two, three, and four dimensions for topology-adaptive multichannel segmentationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2003
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001
- Simultaneous parameter estimation and segmentation of Gibbs random fields using simulated annealingIEEE Transactions on Pattern Analysis and Machine Intelligence, 1989