CE‐LIF chiral separation of aspartic acid and glutamic acid enantiomers using human serum albumin and sodium cholate as dual selectors
Authors:
- 10 September 2009
- journal article
- electrodriven separation
- Published by Wiley in Journal of Separation Science
- Vol. 32 (18) , 3184-3190
Abstract
Sodium cholate (SC), β‐CD, hydroxypropyl (HP)‐β‐CD, HSA, and the dual mixtures of them were evaluated for the analysis of aspartic acid (Asp) and glutamic acid (Glu) enantiomers fluorescently tagged with 5‐(4,6‐dichloro‐s‐triazin‐2‐ylamino) fluorescein (DTAF) by CE with LIF detection. Among the investigated chiral selectors and the dual selector systems, the dual selector systems of HSA and SC resulted to be the most useful chiral selectors allowing relatively high chiral resolution. Several experimental parameters such as chiral reagent type and concentration, buffer concentration, and pH, type and concentration of organic modifier were studied in order to find the optimum conditions for the chiral resolution of the two derivatized amino acids in their enantiomers. The effect of different variables that affect derivatization (time, temperature, pH, and DTAF concentration) was studied. Under optimum conditions, the analytes were separated in a short 10.5 min analysis time, and the RSDs for migration time and peak area were less than 0.12 and 2.8%, respectively. The method was applied for the analysis of compound amino acids injection without interference from other amino acids in the sample matrices observed.Keywords
This publication has 52 references indexed in Scilit:
- Chiral separation of oxprenolol by affinity electrokinetic chromatography-partial filling technique using human serum albumin as chiral selectorJournal of Pharmaceutical and Biomedical Analysis, 2005
- Application of stepwise discriminant analysis to classify commercial orange juices using chiral micellar electrokinetic chromatography‐laser induced fluorescence data of amino acidsElectrophoresis, 2004
- Fast enantiomeric separation of propranolol by affinity capillary electrophoresis using human serum albumin as chiral selector: application to quality control of pharmaceuticalsAnalytica Chimica Acta, 2004
- In vivo simultaneous monitoring of γ‐aminobutyric acid, glutamate, and L‐aspartate using brain microdialysis and capillary electrophoresis with laser‐induced fluorescence detection: Analytical developments and in vitro/in vivo validationsElectrophoresis, 2003
- Capillary electrophoretic separation of glutamate enantiomers in neural samplesElectrophoresis, 2003
- Enantioseparation of o-phthaldiadehyde derivatized amino acids using β-CD-modified micellar electrokinetic chromatography in the mixed aqueous-organic mediaAnalytica Chimica Acta, 2001
- A Comparison of UV and Fluorescence Detectors in the Liquid Chromatographic Analysis of Glyphosate Deposits After Post-Column DerivatizationJournal of Liquid Chromatography & Related Technologies, 1997
- Relationship between Retention and Effective Selector Concentration in Affinity Capillary Electrophoresis and High-Performance Liquid ChromatographyAnalytical Chemistry, 1996
- Presence of free ?-glutamate and ?-aspartate in rat tissuesBiochimica et Biophysica Acta (BBA) - General Subjects, 1995
- Micellar electrokinetic capillary chromatography in a mixture of taurodeoxycholic acid and β-cyclodextrinJournal of the Chemical Society, Chemical Communications, 1992