Stent salvage using the Enterprise stent for procedure-related complication during coil embolization of ruptured intracranial aneurysms
- 10 November 2012
- journal article
- case report
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 155 (2) , 223-229
Abstract
Despite accumulated experience and improved understanding of the tools, endovascular treatment of intracranial aneurysms continues to have risks linked to the technique itself, and induces procedure-related complications. The purpose of this study was to report our series of stent salvage using the Enterprise stent for procedure-related complication during coil embolization in patients with ruptured intracranial aneurysms. Parent artery thrombosis, parent artery dissection, and coil protrusion were considered to be the procedure-related complications. There were 18 consecutive cases (3 unruptured and 15 ruptured aneurysms) with procedure-related complications rescued by the Enterprise stent from December 2008 to December 2011. Follow-up angiography was performed in 14 of the 15 patients with ruptured aneurysms between 6 and 30 months (mean 14.6 months) after the procedure. The procedure-related complications were parent artery dissection (n = 1), parent artery thrombosis (n = 4), and coil protrusion (n = 10). There was no complication related to delivering or deploying of the Enterprise stent. Initial radiographic results showed 8 cases of complete occlusion and 7 cases of neck remnant. There was no change in the angiographic results during the follow-up periods. Facing with procedure-related complications during coil embolization of ruptured intracranial aneurysms, the closed-cell designed Enterprise stent might be a useful option for the salvage technique by restoring blood flow and minimizing thromboembolic events.Keywords
This publication has 18 references indexed in Scilit:
- Stent salvage for parent vessel coil herniation during intracranial aneurysm embolizationSurgical Practice, 2009
- NEUROFORM STENT-ASSISTED COIL EMBOLIZATION OF WIDE-NECK INTRACRANIAL ANEURYSMSNeurosurgery, 2007
- Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysmsNeuroradiology, 2006
- Proximal stent fixation of fractured coils: technical noteNeuroradiology, 2005
- One-stage embolization in patients with acutely ruptured poor-grade aneurysmSurgical Neurology, 2005
- ENDOVASCULAR OCCLUSION OF WIDE-NECKED ANEURYSMS WITH A NEW INTRACRANIAL MICROSTENT (NEUROFORM) AND DETACHABLE COILSNeurosurgery, 2004
- Stent Assisted Coil Embolization: The Treatment of Wide-Necked, Dissecting, and Fusiform AneurysmsInterventional Neuroradiology, 2003
- Parent Vessel Guglielmi Detachable Coil Herniation during Wide-necked Aneurysm Embolization: Treatment with Intracranial Stent Placement: Two Technical Case ReportsNeurosurgery, 2000
- Intracranial Stent Placement to Trap an Extruded Coil During Endovascular Aneurysm Treatment: Technical NoteNeurosurgery, 2000
- Retrieval of a Guglielmi Detachable Coil After Unraveling and FractureNeurosurgery, 1994