Spherical Aberration Customization to Extend the Depth of Focus With a Clinical Adaptive Optics Visual Simulator
Authors:
- Lucía HervellaLHLucía Hervella
- Eloy A. VillegasEVEloy A. Villegas
- Consuelo RoblesCRConsuelo Robles
- Pablo ArtalPAPablo Artal
- 1 April 2020
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (4) , 223-229
Abstract
PURPOSE: To evaluate the use of the VAO adaptive optics visual simulator (Voptica SL, Murcia, Spain) for customization of spherical aberration to increase depth of focus. METHODS: Through-focus visual acuity with both high- and low-contrast letters from +1.00 to −3.00 diopters (D) was measured in 17 dilated eyes with three different induced amounts of spherical aberration for a 4.5-mm pupil diameter: control (0 µm), −0.15 µm, and −0.30 µm. RESULTS: The defocus curves followed the same behavior with both values of contrast, but the visual acuity was 0.2 logMAR lower with low contrast. The mean values of high-contrast logMAR visual acuity at far, intermediate (67 cm), and near (40 cm) were −0.10, 0.11, and 0.37 for control, 0.04, 0.00, and 0.15 for −0.15 µm, and 0.23, 0.00, and 0.06 for −0.30 µm conditions. The 95% confidence interval ranged from ±0.14 to ±0.45 logMAR and the middle 50% of the distribution was approximately 0.2 logMAR. CONCLUSIONS: Negative values of spherical aberration extend the depth of focus in different ways depending on each patient. The VAO is a new instrument that allows the visual customization of spherical aberration to enhance depth of focus. [ J Refract Surg . 2020;36(4):223–229.]Keywords
This publication has 36 references indexed in Scilit:
- Analysis of Higher-Order Aberrations in a Large Clinical PopulationInvestigative Ophthalmology & Visual Science, 2012
- Corneal asphericity and spherical aberration after refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- Hybrid adaptive-optics visual simulatorOptics Letters, 2010
- Expanding depth of focus by modifying higher-order aberrations induced by an adaptive optics visual simulatorJournal of Cataract & Refractive Surgery, 2009
- Use of adaptive optics to determine the optimal ocular spherical aberrationJournal of Cataract & Refractive Surgery, 2007
- Adaptive optics with a programmable phase modulator: applications in the human eyeOptics Express, 2004
- Repeatability of the Waterloo Four‐Contrast LogMAR Visual Acuity chart and Near Vision Test card on a group of normal young adultsOphthalmic and Physiological Optics, 2004
- Neural compensation for the eye’s optical aberrationsJournal of Vision, 2004
- Analysis of the performance of the Hartmann–Shack sensor in the human eyeJournal of the Optical Society of America A, 2000
- Effects of Luminance, Contrast, and Blur on Visual AcuityOptometry and Vision Science, 1995