Contiguous‐slice zonally oblique multislice (CO‐ZOOM) diffusion tensor imaging: Examples of in vivo spinal cord and optic nerve applications
Open Access
- 22 January 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 29 (2) , 454-460
Abstract
Purpose To describe and demonstrate a new technique that allows diffusion tensor imaging of small structures such as the spinal cord (SC) and optic nerve (ON) with contiguous slices and reduced image distortions using a narrow field of view (FOV). Materials and Methods Images were acquired with a modified single‐shot echo‐planar imaging (EPI) sequence that contains a refocusing radio frequency (RF) pulse in the presence of the phase‐encoding (rather than slice‐select) gradient. As a result, only a narrow volume may be both excited and refocused, removing the problem of signal aliasing for narrow FOVs. Two variants of this technique were developed: cardiac gating is included in the study of the SC to reduce pulsation artifacts, whereas inversion‐recovery (IR) cerebrospinal fluid (CSF) suppression is utilized in the study of the ON to eliminate partial volume effects. The technique was evaluated with phantoms, and mean diffusivity (MD) and fractional anisotropy (FA) measurements were made in the SC and ON of two healthy volunteers. Results The technique provides contiguous‐slice, reduced‐FOV images that do not suffer from aliasing and have reduced magnetic susceptibility artifacts. MD and FA values determined here lie within the ranges quoted in the literature. Conclusion Contiguous‐slice zonally orthogonal multislice (CO‐ZOOM‐EPI is a new technique for diffusion‐weighted imaging of small structures such as the ON and SC with high resolution and reduced distortions due to susceptibility variations. This technique is able to acquire contiguous slices that may allow further nerve‐tracking analyses. J. Magn. Reson. Imaging 2009;29:454–460.Keywords
This publication has 21 references indexed in Scilit:
- Diffusion tensor MR imaging of the cervical spinal cord in patients with multiple sclerosisEuropean Radiology, 2007
- High‐resolution DTI of a localized volume using 3D single‐shot diffusion‐weighted STimulated echo‐planar imaging (3D ss‐DWSTEPI)Magnetic Resonance in Medicine, 2006
- In vivo diffusion tensor imaging of the human optic nerve: Pilot study in normal controlsMagnetic Resonance in Medicine, 2006
- High‐resolution DTI with 2D interleaved multislice reduced FOV single‐shot diffusion‐weighted EPI (2D ss‐rFOV‐DWEPI)Magnetic Resonance in Medicine, 2005
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Investigating Cervical Spinal Cord Structure Using Axial Diffusion Tensor ImagingNeuroImage, 2002
- ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF‐suppressed ZOOM‐EPIMagnetic Resonance in Medicine, 2001
- Microstructural and Physiological Features of Tissues Elucidated by Quantitative-Diffusion-Tensor MRIJournal of Magnetic Resonance, Series B, 1996
- DispImage: Un mezzo di analisi e presentazione per iconografia medicaRivista di Neuroradiologia, 1992
- Optic Neuritis and Multiple SclerosisArchives of Neurology, 1985