The Effect of Intermittent Low Speed Mode Upon Aortic Valve Opening in Calves Supported With a Jarvik 2000 Axial Flow Device
Authors:
- Igor D. GregoricIGIgor D. Gregoric
- Jeff L. CongerJCJeff L. Conger
- Kenny GoldenKGKenny Golden
- Robert JarvikRJRobert Jarvik
- O H. FrazierOFO H. Frazier
- Kamuran A. KadipasaogluKKKamuran A. Kadipasaoglu
- 1 March 2005
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 51 (2) , 139-143
Abstract
We assessed the effects of an axial flow left ventricular assist device (LVAD) upon aortic valve opening, pump outflow, and biologic and hematologic parameters when operated in intermittent low speed (ILS) mode. An ILS controller equipped Jarvik 2000 LVAD was implanted in six calves. Pump speed was maintained at 10,000 rpm, and pump outflow was measured throughout the study period (71 ± 6 days [mean ± SD]). Hematologic and biochemical parameters were analyzed daily for the first 10 days, weekly for the first month, and biweekly thereafter to monitor for kidney or liver dysfunction, hemolysis, bleeding, or infection. Before study termination, esmolol hydrochloride was infused to induce low cardiac output and totally impair aortic valve opening. Radiopaque cineaortography was performed over 30 second intervals (10 seconds before, 10 seconds during, and 10 seconds immediately after ILS controller activation) to assess the effect of ILS mode upon aortic valve opening. After study termination, major end organs and the major vascular tree were removed and examined macroscopically and histologically for thrombus formation and infarction; the aortic valve was examined for thickening and fusion. All pumps were explanted and examined for thrombus formation. All six calves recovered without surgical or mechanical complications. Hematologic and biochemical parameters did not change significantly between baseline and study termination. The aortic valve successfully opened when ILS mode was activated, even under low cardiac output conditions. No thrombus was detected in the major end organs and vascular tree, except for some small renal infarcts in three calves that did not affect renal function. These results indicate that operating an axial flow LVAD in ILS mode allows aortic valve opening and aortic root washout.Keywords
This publication has 19 references indexed in Scilit:
- Spontaneous echocardiographic contrast in the ascending aorta mimicking the appearance of aortic dissection in a patient with a left ventricular assist device.Echocardiography, 2004
- In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2004
- Use of the Flowmaker (Jarvik 2000) Left Ventricular Assist Device for Destination Therapy and Bridging to TransplantationCardiology, 2004
- Myocardial Hemodynamics, Physiology, and Perfusion With an Axial Flow Left Ventricular Assist Device in the CalfASAIO Journal, 2004
- Acquired commissural fusion of aortic valves in patients with left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2003
- Total left ventricular outflow tract obstruction due to left ventricular assist device–induced sub-aortic thrombosis in 2 patients with aortic valve bioprosthesisThe Journal of Heart and Lung Transplantation, 2003
- Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantationThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Effects of Left Ventricular Assist Device on Cardiac Function: Experimental Study of Relationship between Pump Flow and Left Ventricular Diastolic FunctionArtificial Organs, 2001
- Partial aortic valve fusion induced by left ventricular assist deviceThe Annals of Thoracic Surgery, 2000
- Left ventricular assist system as a bridge to myocardial recoveryThe Annals of Thoracic Surgery, 1999