Neurologically Intact Survival in a Porcine Model of Cardiac Arrest: Manual Cardiopulmonary Resuscitation vs. LifeBelt Cardiopulmonary Resuscitation
Authors:
- Scott T. YoungquistSYScott T. Youngquist
- James T. NiemannJNJames T. Niemann
- W. Gary AllreadW. Gary Allread
- Theodore HeymingTHTheodore Heyming
- John P. RosboroughJRJohn P. Rosborough
- Msc MdMMMsc Md
- MdMDMd
- CPE PhDCPCPE PhD
- Ph DPDPh D
- 13 April 2010
- journal article
- research article
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 14 (3) , 324-328
Abstract
To compare the LifeBelt (Deca-Medica, Inc., Columbus, OH), a novel cardiopulmonary resuscitation (CPR) device, with manual CPR on the outcome of neurologically intact survival in a porcine model of cardiac arrest. Twenty-two adolescent swine were randomized by permuted block design to resuscitation using LifeBelt (n = 12) or manual CPR (n = 10). The animals were instrumented with right atrial and aortic pressure catheters while they were under general anesthesia with isoflurane and nitrous oxide. Ventricular fibrillation (VF) was induced with a bipolar pacing catheter placed in the right ventricle. After 7 minutes of untreated VF, chest compressions with either LifeBelt or manual CPR were initiated along with standard Advanced Cardiac Life Support. Survivors were assigned a neurologic score using the neurologic deficit score and the cerebral performance category (CPC) score at 24, 48, and 72 hours following resuscitation by a veterinarian blinded to treatment allocation. There were no significant differences in prearrest hemodynamic parameters or in important resuscitation variables between the groups. One of 12 of the LifeBelt animals failed to achieve return of spontaneous circulation (0.08, 95% confidence interval [CI] 0.002-0.38). The remaining 11 had a neurologic deficit score of 0 and a CPC score of 1, indicating normal neurologic function. All of the manual CPR animals survived. One of 10 manual CPR survivors (0.10, 95% CI 0.003-0.45) had a neurologic deficit score of 260 and a CPC score of 3, indicating moderate disability, while the remaining animals had a neurologic deficit score of 0 and a CPC score of 1. In this porcine model of cardiac arrest, we did not detect significant differences in neurologically intact survival between LifeBelt CPR and manual CPR.Keywords
This publication has 24 references indexed in Scilit:
- Understanding and enhancing functional outcomes after cardiac arrest: The need for a multidisciplinary approach to refocus on the brainResuscitation, 2009
- Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational studyBMC Medicine, 2009
- Minimally Interrupted Cardiac Resuscitation by Emergency Medical Services for Out-of-Hospital Cardiac ArrestJAMA, 2008
- Mechanical devices for cardiopulmonary resuscitationCurrent Opinion in Critical Care, 2007
- Epidemiology, trends, and outcome of out-of-hospital cardiac arrest of non-cardiac originResuscitation, 2007
- Increased survival despite a reduction in out-of-hospital ventricular fibrillation in north-east ItalyResuscitation, 2007
- A new device producing manual sternal compression with thoracic constraint for cardiopulmonary resuscitationResuscitation, 2006
- The Changing Incidence of Ventricular Fibrillation in Milwaukee, Wisconsin (1992–2002)Prehospital Emergency Care, 2006
- Trends in treated ventricular fibrillation out-of-hospital cardiac arrest: A 17-year population-based studyHeart Rhythm, 2004
- Changing Incidence of Out-of-Hospital Ventricular Fibrillation, 1980-2000JAMA, 2002