Abstract
To increase the performance for detecting small shifts, control charts are used with runs rules. The Western Electrical Handbook ( 1956 Western Electrical Company ( 1956 ). Statistical Quality Control Handbook . Indianapolis . [Google Scholar] ) suggests runs rules to be used with the Shewhart chart. In this article, we review the performance of two sets of runs rules. The rules of one set signal if k succesive points fall beyond a limit. The rules of the other set signal if k out of k + 1 consecutive points fall beyond a different limit. We suggest runs rules from these sets. They are intended to be used with a modified Shewhart chart, a chart with 3.3 σ limits. We find that for small shifts all suggested charts have improved performance than the Shewhart chart. For large shifts they have comparable performance.

This publication has 7 references indexed in Scilit: