Preservation of residual hearing following cochlear implantation: comparison between three surgical techniques
Authors:
- S BerrettiniSBS Berrettini
- F ForliFFF Forli
- S PassettiSPS Passetti
- 1 August 2007
- journal article
- research article
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 122 (3) , 246-252
Abstract
The preservation of residual hearing is becoming a high priority in cochlear implant surgery. It allows better speech understanding and ensures long-lasting and stable performance; it also allows the possibility, in selected cases, of combining electro-acoustic stimulation in the same ear.We present the results of a retrospective study of the conservation of residual hearing in three different groups of patients who had undergone cochlear implantation using three different cochlear implant electrode arrays, combined with three different surgical techniques for the cochleostomy. The study aimed to evaluate which approach allowed greater preservation of residual hearing.The best residual hearing preservation results (i.e. preservation in 81.8 per cent of patients) were achieved with the Contour Advance electrode array, using the Advance Off-Stylet technique and performing a modified anterior inferior cochleostomy; this combination enabled reduced trauma to the lateral wall of the cochlea during electrode insertion.Keywords
This publication has 24 references indexed in Scilit:
- Residual Hearing Conservation and Electroacoustic Stimulation with the Nucleus 24 Contour Advance Cochlear ImplantOtology & Neurotology, 2006
- A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour™ electrodesHearing Research, 2005
- Evaluation des Insertionstraumas des Nucleus® Contour Advance™-Elektrodenträgers im humanen FelsenbeinmodellLaryngo-Rhino-Otologie, 2004
- Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion studyActa Oto-Laryngologica, 2004
- Development and Evaluation of an Improved Cochlear Implant Electrode Design for Electric Acoustic StimulationThe Laryngoscope, 2004
- Evaluation of the HiFocus® electrode array with positioner in human temporal bonesThe Journal of Laryngology & Otology, 2003
- Comparative Study of Cochlear Damage With Three Perimodiolar Electrode DesignsThe Laryngoscope, 2003
- The Nucleus Contour Electrode Array: A Radiological and Histological StudyThe Laryngoscope, 2001
- Perimodiolar Electrodes in Cochlear Implant SurgeryActa Oto-Laryngologica, 2001
- Cochlear view: Postoperative radiography for cochlear implantationAmerican Journal of Otolaryngology, 2000