Abstract
Purpose: To describe a method for converting Zero TE (ZTE) MR images into X‐ray attenuation information in the form of pseudo‐CT images and demonstrate its performance for (1) attenuation correction (AC) in PET/MR and (2) dose planning in MR‐guided radiation therapy planning (RTP).Methods: Proton density‐weighted ZTE images were acquired as input for MR‐based pseudo‐CT conversion, providing (1) efficient capture of short‐lived bone signals, (2) flat soft‐tissue contrast, and (3) fast and robust 3D MR imaging. After bias correction and normalization, the images were segmented into bone, soft‐tissue, and air by means of thresholding and morphological refinements. Fixed Hounsfield replacement values were assigned for air (‐1000 HU) and soft‐tissue (+42 HU), whereas continuous linear mapping was used for bone.Results: The obtained ZTE‐derived pseudo‐CT images accurately resembled the true CT images (i.e., Dice coefficient for bone overlap of 0.73 ± 0.08 and mean absolute error of 123 ± 25 HU evaluated over the whole head, including errors from residual registration mismatches in the neck and mouth regions). The linear bone mapping accounted for bone density variations. Averaged across five patients, ZTE‐based AC demonstrated a PET error of ‐0.04 ± 1.68% relative to CT‐based AC. Similarly, for RTP assessed in eight patients, the absolute dose difference over the target volume was found to be 0.23 ± 0.42%.Conclusion: The described method enables MR to pseudo‐CT image conversion for the head in an accurate, robust, and fast manner without relying on anatomical prior knowledge. Potential applications include PET/MR‐AC, and MR‐guided RTP.Keywords
This publication has 57 references indexed in Scilit:
- A review of substitute CT generation for MRI-only radiation therapyRadiation Oncology, 2017
- Vision 20/20: Magnetic resonance imaging‐guided attenuation correction in PET/MRI: Challenges, solutions, and opportunitiesMedical Physics, 2016
- MRI in radiation oncology: Underserved needsMagnetic Resonance in Medicine, 2015
- MR-based attenuation correction for PET/MRI neurological studies with continuous-valued attenuation coefficients for bone through a conversion from R2* to CT-Hounsfield unitsNeuroImage, 2015
- Comparison of 4-Class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation CorrectionIEEE Transactions on Nuclear Science, 2013
- MR-Based PET Attenuation Correction for PET/MR ImagingSeminars in Nuclear Medicine, 2013
- CT substitute derived from MRI sequences with ultrashort echo timeMedical Physics, 2011
- Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain PrototypeJournal of Nuclear Medicine, 2010
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT DataJournal of Nuclear Medicine, 2009