Abstract
Studies of skeletal metabolism using measurements of bone metabolic flux (Ki) obtained with [18F] sodium fluoride ([18F]NaF) positron emission tomography (PET) scans have been used in clinical research for the last 30 years. The technique has proven useful as an imaging biomarker in trials of novel drug treatments for osteoporosis and investigating other metabolic bone diseases, including chronic kidney disease mineral and bone disorder. It has also been shown to be valuable in metastatic bone disease in breast cancer patients and may have potential in other cancer types, such as prostate cancer, to assess early bone fracture risk. However, these studies have usually required a 60‐min dynamic PET scan and measurement of the arterial input function (AIF), making them difficult to translate into the clinic for diagnostic purposes. We have previously proposed a simplified method that estimates the Ki value at an imaging site from a short (4‐min) static scan and venous blood samples. A key advantage of this method is that, by acquiring a series of static scans, values of Ki can be quickly measured at multiple sites using a single injection of the tracer. To date, the widespread use of [18F]NaF PET has been limited by the need to measure the AIF required for the mathematical modeling of tracer kinetics to derive Ki and other kinetic parameters. In this report, we review different methods of measuring the AIF, including direct arterial sampling, the use of a semi‐population input function (SP‐AIF), and image‐derived input function, the latter two requiring only two or three venous blood samples obtained between 30 and 60 min after injection. We provide an SP‐AIF model and a spreadsheet for calculating Ki values using the static scan method that others can use to study bone metabolism in metabolic and metastatic bone diseases without requiring invasive arterial blood sampling. The method shortens scan times, simplifies procedures, and reduces the cost of multicenter trials without losing accuracy or precision.Keywords
This publication has 59 references indexed in Scilit:
- 18F-fluoride PET as a noninvasive imaging biomarker for determining treatment efficacy of bone active agents at the hip: A prospective, randomized, controlled clinical studyJournal of Bone and Mineral Research, 2013
- Comparison of six quantitative methods for the measurement of bone turnover at the hip and lumbar spine using 18F-fluoride PET-CTNuclear Medicine Communications, 2012
- The Precision and Sensitivity of18F-Fluoride PET for Measuring Regional Bone Metabolism: A Comparison of Quantification MethodsJournal of Nuclear Medicine, 2011
- Validation of image-derived arterial input functions at the femoral artery using 18F-fluoride positron emission tomographyNuclear Medicine Communications, 2011
- Validation of new image-derived arterial input functions at the aorta using 18F-fluoride positron emission tomographyNuclear Medicine Communications, 2011
- Kinetic Analysis of18F-Fluoride PET Images of Breast Cancer Bone MetastasesJournal of Nuclear Medicine, 2010
- Differences in regional bone perfusion and turnover between lumbar spine and distal humerus: 18F-fluoride PET study of treatment-naïve and treated postmenopausal womenBone, 2009
- Effects Of a One-Month Treatment With PTH(1–34) on Bone Formation on Cancellous, Endocortical, and Periosteal Surfaces of the Human IliumJournal of Bone and Mineral Research, 2007
- Differences in Skeletal Kinetics Between Vertebral and Humeral Bone Measured by 18F-Fluoride Positron Emission Tomography in Postmenopausal WomenJournal of Bone and Mineral Research, 2000
- Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. GeneralizationsJournal of Cerebral Blood Flow & Metabolism, 1985