The gamma camera as an absolute measurement device: Determination of glomerular filtration rate in 99mTc-DTPA renography using a dual head gamma camera
Author:
- 1 October 2004
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 25 (10) , 1021-1029
Abstract
The aim of this study was to design a general nuclear medicine method for fast, accurate and direct determination of the clearance of a radioactive indicator provided that all uptake compartments of the radioactive indicator could be included in the field of view of the gamma camera. The data material for clearance calculation in the gamma camera method (GCM) comprises: (1) a transmission map of a part of the body using a water filled flood field phantom with a uniform distribution of the radioisotope, (2) the background corrected activity curves in the anterior and posterior views over all uptake compartments following the injection of the radioactive indicator, and (3) the activity of the radioactive indicator in at least two blood samples drawn during the examination. With a view to determining glomerular filtration rate (GFR) in 99mTc-DTPA renography the gamma camera method was tested in a group of 26 adult subjects in whom GFR was determined simultaneously using the simplified multiple samples method (MSM) with plasma samples drawn 3-5 h following the injection of 51Cr-EDTA. For values of GFR above 30 ml.min(-1) the regression line of GFR in the MSM versus GFR in the GCM was not significantly different from the line of identity. The reliability of the GCM alone was about 14%, 11% and 6% for GFR values of 30, 60 and 120 ml.min(-1) and, therefore, the reliability of the GCM and the simplified MSM for prediction of GFR was almost the same. Since the recording of the renal count rates in the anterior and posterior views permits an accurate determination of the split renal function, the GCM yields reliable estimates also of the single kidney GFR.Keywords
This publication has 10 references indexed in Scilit:
- Conventional measurements of GFR using 51 Cr-EDTA overestimate true renal clearance by 10 percentEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with99mTc-DTPAAnnals of Nuclear Medicine, 2000
- Measurement of glomerular filtration rate with 99mTc-DTPA: A comparison of gamma camera methodsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1987
- Renal fraction of cardiac output cleared of radioactive indicator in 99Tcm-DTPA gamma camera renographyNuclear Medicine Communications, 1987
- Estimation of glomerular filtration rate using 99mTc-DTPA and the gamma cameraEuropean Journal of Nuclear Medicine and Molecular Imaging, 1987
- 99mTc-DTPA gamma-camera renography: Normal values and rapid determination of single-kidney glomerular filtration rateEuropean Journal of Nuclear Medicine and Molecular Imaging, 1985
- Comparative assessment of techniques for estimation of glomerular filtration rate with 99mTc-DTPAEuropean Journal of Nuclear Medicine and Molecular Imaging, 1985
- Glomerular filtration rate: estimation from fractional renal accumulation of 99mTc-DTPA (stannous)American Journal of Roentgenology, 1982
- A simple method for measuring separate glomerular filtration rate using a single injection of 99mTc-DTPA and the scintillation cameraThe Journal of Pediatrics, 1978
- Comparison between Total and Renal Plasma Clearance of [51Cr]EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1976