Indirect Differential Pulse Voltammetric Determination of Aluminum by a Pyrocatechol Violet-Modified Electrode
Authors:
- Gang ChenGCGang Chen
- Shuping BiSBShuping Bi
- Lemei DaiLDLemei Dai
- Mi CaoMCMi Cao
- Yijun ChenYCYijun Chen
- Xiaoshu WangXWXiaoshu Wang
- 1 January 1999
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 32 (5) , 865-883
Abstract
A Pyrocatechol Violet (PCV) modified electrode for the voltammetric determination of aluminum is reported. The modified electrode is simply prepared by dip-coating a pyrolytic graphite electrode in a NaAc-HAc buffer solution of PCV. Optimum experimental conditions for aluminum determination include a 0.2 mol/L NaAc-HAc buffer solution of pH 4.8, a PCV concentration of 0.02 mol/L used to modify the electrode and the use of differential-pulse mode for measurement. The peak currents of differential pulse voltammograms (DPV) decrease with the addition of Al into the buffer solution while the peak potentials remain the same. The decreasing value of peak current ▵ip is linear with Al concentration in the range of 1x10−8 to 1x10−7 mol/L and 1x10−7 to 1x10−6 mol/L. The detection limit is 5x10−9 mol/L and the relative standard deviation for 4x10−8 mol/L Al is 2.9% (n=8). The stability of this electrode is satisfactory. No serious interference is found. This method has been applied to determine Al in drinking water samples.Keywords
This publication has 15 references indexed in Scilit:
- Determination of aluminium in tree samples by cathodic adsorptive stripping voltammetryTalanta, 1997
- Studies of the preparation and analytical application of polypyrrole‐coated microelectrodes for determination of aluminumElectroanalysis, 1996
- On-line aluminium preconcentration on chelating resin and its FIA-spectrofluorimetric determination in foods and dialysis concentratesTalanta, 1991
- Voltammetric determination of aluminium(III) using a chemically modified electrodeAnalytica Chimica Acta, 1991
- Voltammetric determination of Al(III) with adsorptive preconcentration of the pyrocatechol violet complexCanadian Journal of Chemistry, 1991
- Extraction spectrophotometric method for determination of aluminium in silicatesTalanta, 1990
- Matrix effects in the determination of aluminium in dialysis fluids by graphite furnace atomic absorption spectrometryThe Analyst, 1987
- Stripping voltammetry of aluminum based on adsorptive accumulation of its solochrome violet RS complex at the static mercury drop electrodeAnalytica Chimica Acta, 1985
- Evaluation of the L'vov platform and matrix modification for the determination of aluminium in serumThe Analyst, 1985
- EFFECTS OF ALUMINUM, OHSoil Science, 1983