Performance-Based Compositive Passive Control Analysis of Multi-Tower Building with Chassis: Optimization of Kelvin-Voigt Dampers
Open Access
Abstract
The compositive passive control (CPC) method of “interlayer seismic isolation “plus “shock absorption between adjacent towers” was applied to a multi-tower building (MTB) with a large podium. The interaction between adjacent towers was used to reduce the structural response under seismic action. Based on the Clough–Penzien spectral seismic model, the extended state equation of random response of MTB was derived with the minimum total energy of structural vibration as the optimization control objective. By comparing the seismic scheme and interlayer seismic isolation scheme, the relationship between the control parameters of the connecting control device and the random response of the structure was discussed and analyzed, and the control effect of the composite passive control system under different control schemes was also studied from the perspective of seismic response time history and vibration cumulative energy time history. Through numerical analysis, it was proved that the damping coefficient of the Kelvin-Voigt model has a great influence on the mean square error of total vibration energy while the stiffness coefficient has a poor sensitivity to it. Under the optimization control objective, the connection control device was better arranged at the top of the structure. The control effect can reach 84.64% under the condition of random ground motion as input. The CPC method maintains the advantages of the interlayer seismic isolation scheme and reduces the defect of the response amplification caused by the interlayer isolation, which provides a reference for the follow-up study of the CPC method of MTB.Keywords
Funding Information
- NingXia Natural Science Foundation of China (2021AAC05003)
- National Natural Science Foundation of China (51908129)
- Project of Young Scholars in the West (XAB2017AW09)
This publication has 29 references indexed in Scilit:
- Random response analysis of adjacent structures connected with friction damperAsian Journal of Civil Engineering, 2021
- Seismic performance evaluation of tall, multitower reinforced concrete buildings with large bottom podiumsStructural Concrete, 2018
- Effects of podium interference on shear force distributions in tower walls supporting tall buildingsEngineering Structures, 2017
- A novel reliability technique for implementation of Performance-Based Seismic Design of structuresEngineering Structures, 2017
- Simplified analysis of mid‐story seismically isolated buildingsEarthquake Engineering & Structural Dynamics, 2011
- Performance-based seismic design of structures: a direct displacement-based approachEngineering Structures, 2003
- Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampersEarthquake Engineering & Structural Dynamics, 1999
- Experimental investigation of adjacent buildings connected by fluid damperEarthquake Engineering & Structural Dynamics, 1999
- Random vibration and statistical linearizationJournal of Sound and Vibration, 1990
- Semi-Active Control of Wind Induced Oscillations in Structures1987