Selective-site pacing in paediatric patients: a new application of the Select Secure system
Open Access
- 5 March 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 11 (5) , 601-606
Abstract
The aim of this study was to evaluate the feasibility and reliability of selective-site pacing by means of a new lead system in a paediatric population. This lead system is composed of a 4.1 Fr, active-fixation lead and a steerable catheter that allows easy positioning in selective sites. Thirty young patients (mean age 9.0 ± 4.5 years, range 2–16 years) received a single- (10) or dual- (20) chamber pacemaker. The 3830 lead was implanted successfully in the targeted chambers in all patients. The selective RV sites of pacing in 26 of the patients were: 18 mid-septum, 5 outflow tract, 1 low-septum, and 2 LEVO-RV-Apex. In all patients, an intracardiac loop was left in order to avoid stretching of the lead with growth. Mean follow-up duration was 11 ± 10 months. Atrial sensing and pacing thresholds were 3.2 ± 1.7 mV and 0.8 ± 0.6 V at 0.5 ms at implantation and 3.4 ± 2.1 mV and 0.6 ± 0.3 V at 0.5 ms at follow-up. Ventricular sensing and pacing thresholds were 12.1 ± 4.9 and 0.7 ± 0.4 V at 0.5 ms on implantation and 12.7 ± 6.1 mV and 0.8 ± 0.5 V at 0.5 ms at follow-up ( P = NS). No adverse events were reported. Select Secure is a promising system for selective-site pacing in children.Keywords
This publication has 16 references indexed in Scilit:
- Implantation of SelectSecure? Leads in ChildrenPacing and Clinical Electrophysiology, 2007
- Evolution of left ventricular function in paediatric patients with permanent right ventricular pacing for isolated congenital heart block: a medium term follow-upEP Europace, 2007
- Validation of Criteria for Selective His Bundle and Para‐Hisian Permanent PacingPacing and Clinical Electrophysiology, 2006
- Multi‐Center Clinical Experience with a Lumenless, Catheter‐Delivered, Bipolar, Permanent Pacemaker Lead: Implant Safety and Electrical PerformancePacing and Clinical Electrophysiology, 2006
- Twenty years of paediatric cardiac pacing: 515 pacemakers and 480 leads implanted in 292 patientsEP Europace, 2006
- The Deleterious Consequences of Right Ventricular Apical Pacing: Time to Seek Alternate Site PacingPacing and Clinical Electrophysiology, 2006
- Chronic Right Ventricular Pacing and Cardiac Performance:Pacing and Clinical Electrophysiology, 2004
- Left ventricular dysfunction after long-term right ventricular apical pacing in the youngJACC, 2001
- Altered Cardiac Histology Following Apical Right Ventricular Pacing in Patients with Congenital Atrioventricular BlockPacing and Clinical Electrophysiology, 1999
- Comparative Left Ventricular Function Following Atrial, Septal, and Apical Single Chamber Heart Pacing in the YoungPacing and Clinical Electrophysiology, 1997