Sulphur Poisoning and Regeneration of NOx Trap Catalyst for Direct Injected Gasoline Engines
- 25 October 1999
- conference paper
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Abstract
Sulphur poisoning and regeneration of NOx trap catalysts have been studied in synthetic exhausts and in an engine bench. Sulphur gradually poisoned the NOx storage sites in the axial direction of the NOx trap. During sulphur regenerations, hydrogen was found to be more efficient than carbon monoxide in removing the sulphur from the trap. The sulphur regeneration became more efficient the richer the environment (λ<1) and the higher the temperature (at least 600°C). H2S was found to be the main product during the sulphur regeneration. However, it was possible to reduce the H2S formation and instead produce more SO2 by running with lambda close to one or by pulsing lambda. Even if a relatively large amount of sulphur was removed from the NOx trap, these methods gave a much less efficient regeneration per sulphur atom removed than when running relatively rich constantly. Finally, a model that could explain this observation was proposed.Keywords
This publication has 7 references indexed in Scilit:
- NOxStorage in Barium-Containing CatalystsJournal of Catalysis, 1999
- Durability Aspects of NOx Storage Catalysts for Direct Injection Gasoline VehiclesSAE International Journal of Advances and Current Practices in Mobility, 1999
- Global Warming1997
- Study of NOx Trap Reaction by Thermodynamic CalculationSAE International Journal of Advances and Current Practices in Mobility, 1997
- New Developments in Lean NOx Catalysis for Gasoline Fueled Passenger Cars in EuropeSAE International Journal of Advances and Current Practices in Mobility, 1996
- The new concept 3-way catalyst for automotive lean-burn engine: NOx storage and reduction catalystCatalysis Today, 1996
- A flow reactor system for catalytic reaction studies, allowing time- and space-resolved measurements of gas composition and temperature around the catalystReview of Scientific Instruments, 1994