Experimental study of the liquid flow near a single sonoluminescent bubble

Authors:

Abstract
Tracers (sulphur particles produced in situ by a bubble itself, fuchsin spots and dust) were used to probe the liquid flows in the neighborhood of single sonoluminescent bubbles maintained in levitation in a resonant acoustic setup. The flows caused by the bubble were distinguished clearly from the streamings (mean Lagrangian velocity: ∼20 μm/s) associated with resonant cells in the absence of a bubble. The liquid flow due to the presence of the bubble formed around it over a few mm. The radial component of the Lagrangian velocities (maximum value measured: ∼260 μm/s) of this flow evolved as r−1, with r as the distance from the bubble, while the tangential component remained approximately constant (∼20 μm/s). In the Appendix by M. S. Longuet-Higgins, a simplified model of microstreaming involving a spherical bubble in translational and radial oscillation gives a qualitative description of the experiments. A fairly good agreement was observed between the experiments and the modeling, which involved a dipole flow enclosed in a Stokeslet.

This publication has 19 references indexed in Scilit: