Corneal Allogenic Intrastromal Ring Segments (CAIRS) Versus Synthetic Segments: A Single Segment Comparative Analysis Using Propensity Score Matching
Authors:
- 1 November 2024
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 40 (11) , e863-e876
Abstract
Purpose: To compare and assess the visual, refractive, and tomographic results of patients with corneal ectasia treated with either corneal allogenic intrastromal ring segments (CAIRS) or synthetic intrastromal corneal ring segments (ICRS) without concomitant corneal cross-linking. Methods: In this retrospective cohort study, 34 eyes with CAIRS were matched to 34 eyes with ICRS using the propensity score matching technique. Each group was matched on a oneto-one basis using multiple parameters such as central corneal thickness, vertical and horizontal coma, maximum anterior keratometry, steepest keratometry, and age. Visual, refractive, topographic, and aberrometric data were measured at baseline, 1 week, 1 month, 3 months, and 1 year postoperatively. Results: Initial preoperative parameters were similar between the two groups. Both groups showed significant improvement at last follow-up time in corrected distance visual acuity (CDVA) (0.52 ± 0.23 to 0.16 ± 0.18 logarithm of the minimum angle of resolution [logMAR], P < .001; 0.44 ± 0.27 to 0.17 ± 0.21 logMAR, P < .001), topographic astigmatism (4.45 ± 2.75 to 3.14 ± 1.93 diopters [D], P = .001; 3.66 ± 2.22 to 2.36 ± 1.46 D, P = .007), maximum anterior keratometry (55.85 ± 7.53 to 50.69 ± 6.38 D, P < .001; 54.59 ± 6.95 to 50.71 ± 4.51 D, P = .003), and vertical coma (1.49 ± 1.02 to 0.38 ± 0.65 D, P < .001; 1.22 ± 0.75 to 0.52 ± 0.57 D, P < .001) for CAIRS and ICRS, respectively. The improvements observed in both groups at the last follow-up visit were comparable; however, the CAIRS group demonstrated a higher percentage of eyes gaining two or more Snellen lines of CDVA (60% vs 31.58%, P = .04), and a greater magnitude of reduction in vertical coma compared to the ICRS group, although this difference did not reach statistical significance. No major complications were observed with both groups, and one eye lost one CDVA line in the ICRS group. The mean thickness of the CAIRS segments at the last follow-up visit was 401.06 ± 100.12 µm, compared to 435.29 ± 26.19 µm for ICRS. Both CAIRS and ICRS demonstrated significant compression of stromal thickness above the segment (36.19% and 32.00%, respectively). Conclusions: When adequately matched for preoperative disease type and severity, eyes with CAIRS had a similar and notable clinical improvement compared to ICRS, with possibly better improvement in vertical coma and CDVA. [ J Refract Surg . 2024;40(11):e863–e876.]Keywords
This publication has 38 references indexed in Scilit:
- Allogenic corneal tissue transplantation in substitution for extruded intracorneal rings: A case seriesJournal Français d'Ophtalmologie, 2019
- Tomographic and Refractive Characteristics of Pediatric First-Degree Relatives of Keratoconus PatientsAmerican Journal of Ophthalmology, 2019
- Corneal Hydrops Secondary to Intrastromal Corneal Ring Intrusion into the Anterior Chamber 7 Years after Implantation: A Case ReportOphthalmology and Therapy, 2017
- Precision (repeatability and reproducibility) studies and sample-size calculationJournal of Cataract & Refractive Surgery, 2015
- Refractive and topographic effects of single-segment intrastromal corneal ring segments in eyes with moderate to severe keratoconus and inferior conesJournal of Cataract & Refractive Surgery, 2015
- Expanding the Cone Location and Magnitude Index to Include Corneal Thickness and Posterior Surface Information for the Detection of KeratoconusAmerican Journal of Ophthalmology, 2013
- Late dislocation of intrastromal corneal ring segment into the anterior chamberJournal of Cataract & Refractive Surgery, 2010
- Refractive and Aberrometric Outcomes of Intracorneal Ring Segments for Keratoconus: Mechanical versus Femtosecond-assisted ProceduresOphthalmology, 2009
- Intracorneal ring segments for keratoconus correction: Long-term follow-upJournal of Cataract & Refractive Surgery, 2006
- The Intrastromal Corneal Ring SegmentsOphthalmology, 1997