Deriving the modulation transfer function of CT from extremely noisy edge profiles
Authors:
- 1 January 2009
- journal article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 2 (1) , 22-32
Abstract
The point spread function (PSF) method is currently the one predominantly used to determine the modulation transfer function (MTF) of an X-ray CT system. However, the image examined with the PSF method must have a very high contrast-to-noise ratio (CNR); it must also be reconstructed with a fine pixel pitch using a zooming reconstruction. Therefore, the PSF method is often inappropriate for describing the MTF of clinical operating conditions when image linearity is not guaranteed. The edge spread function (ESF) method requires no zooming reconstruction, but its susceptibility to image noise is no better than that of the PSF method. We describe a technique for rendering the ESF method robust to image noise. We smooth out the noisy ESF through multiple stages of filtering. Invariably, the line spread function (LSF) obtained from the smoothed ESF is blurred, and the MTF obtained from the LSF is incorrect. However, because the filtering that has been applied is known, much of the LSF blurring can be corrected. An estimate of the true LSF is obtainable from the blurred LSF, assuming that the true LSF is not very different from either a Gaussian or a composite of multiple Gaussians. For an image reconstructed with a kernel for soft-tissue imaging, the MTF obtained by our method is sufficiently consistent with the theoretical MTF, even when the CNR is as low as 2.Keywords
This publication has 15 references indexed in Scilit:
- The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCTEuropean Radiology, 2007
- New Method of Evaluating Edge-preserving Adaptive Filters for Computed Tomography (CT): Digital Phantom MethodJapanese Journal of Radiological Technology, 2006
- Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot StudyRadiology, 2003
- Determination of the presampled MTF in computed tomographyMedical Physics, 2001
- Principles of Computerized Tomographic Imaging2001
- A simple method for determining the modulation transfer function in digital radiographyIEEE Transactions on Medical Imaging, 1992
- A simplified approach for modulation transfer function determinations in computed tomographyMedical Physics, 1985
- Transfer function analysis of radiographic imaging systemsPhysics in Medicine & Biology, 1979
- Computed Tomography with Fan Beam GeometryJournal of Computer Assisted Tomography, 1977
- The line spread function and modulation transfer function of a computed tomographic scannerMedical Physics, 1976