High-Resolution Ambient MS Imaging of Negative Ions in Positive Ion Mode: Using Dicationic Reagents with the Single-Probe
Authors:
Open Access
- 21 October 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 27 (1) , 124-134
Abstract
We have used the Single-probe, a miniaturized sampling device utilizing in-situ surface microextraction for ambient mass spectrometry (MS) analysis, for the high resolution MS imaging (MSI) of negatively charged species in the positive ionization mode. Two dicationic compounds, 1,5-pentanediyl-bis(1-butylpyrrolidinium) difluoride [C5(bpyr)2F2] and 1,3-propanediyl-bis(tripropylphosphonium) difluoride [C3(triprp)2F2], were added into the sampling solvent to form 1+ charged adducts with the negatively charged species extracted from tissues. We were able to detect 526 and 322 negatively charged species this way using [C5(bpyr)2F2] and [C3(triprp)2F2], respectively, including oleic acid, arachidonic acid, and several species of phosphatidic acid, phosphoethanolamine, phosphatidylserine, phosphatidylglycerol, phosphatidylinositol, and others. In conjunction with the identification of the non-adduct cations, we have tentatively identified a total number of 1200 and 828 metabolites from mouse brain sections using [C5(bpyr)2F2] and [C3(triprp)2F2], respectively, through high mass accuracy measurements (mass error <5 ppm); MS/MS analyses were also performed to verify the identity of selected species. In addition to the high mass accuracy measurement, we were able to generate high spatial resolution (~17 μm) MS images of mouse brain sections. Our study demonstrated that utilization of dicationic compounds in the surface microextraction with the Single-probe device can perform high mass and spatial resolution ambient MSI measurements of broader types of compounds in tissues. Other reagents can be potentially used with the Single-probe device for a variety of reactive MSI studies to enable the analysis of species that are previously intractable.Keywords
This publication has 50 references indexed in Scilit:
- Reactive DESI-MS Imaging of Biological Tissues with Dicationic Ion-Pairing CompoundsAnalytical Chemistry, 2015
- Mass Spectrometry Imaging of Biomolecular InformationAnalytical Chemistry, 2014
- Transmission geometry laser ablation into a non‐contact liquid vortex capture probe for mass spectrometry imagingRapid Communications in Mass Spectrometry, 2014
- Automated Platform for High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 2012
- Improved spatial resolution in the imaging of biological tissue using desorption electrospray ionizationAnalytical and Bioanalytical Chemistry, 2012
- Matrix Sublimation/Recrystallization for Imaging Proteins by Mass Spectrometry at High Spatial ResolutionAnalytical Chemistry, 2011
- Mapping Lipid Alterations in Traumatically Injured Rat Spinal Cord by Desorption Electrospray Ionization Imaging Mass SpectrometryAnalytical Chemistry, 2010
- Desorption electrospray ionization imaging mass spectrometry of lipids in rat spinal cordJournal of the American Society for Mass Spectrometry, 2010
- Desorption electrospray ionization and other ambient ionization methods: current progress and previewThe Analyst, 2010
- Evaluation of a surface‐sampling probe electrospray mass spectrometry system for the analysis of surface‐deposited and affinity‐captured proteinsRapid Communications in Mass Spectrometry, 2006