Proximal tibial strain in medial unicompartmental knee replacements
- 1 October 2013
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 95-B (10) , 1339-1347
Abstract
As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves (‘hits’) produced when damage occurs in material.Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint.Cite this article: Bone Joint J 2013;95-B:1339–47.Keywords
This publication has 33 references indexed in Scilit:
- Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamageJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Minimally invasive Oxford phase 3 unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Elevated proximal tibial strains following unicompartmental knee replacement—A possible cause of painMedical Engineering & Physics, 2009
- Unicompartmental or total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- In vivo medial and lateral tibial loads during dynamic and high flexion activitiesJournal of Orthopaedic Research, 2007
- Particle size of bone graft and method of impaction affect initial stability of cemented cupsHuman cadaveric and synthetic pelvic specimen studiesActa Orthopaedica, 2003
- Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentationJournal of Biomechanics, 2002
- Oxford medial unicompartmental knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2001
- Mechanical properties of osteopenic vertebral bodies monitored by acoustic emissionBone, 1993
- Acoustic emission and mechanical properties of trabecular boneBiomaterials, 1985