Proton dose calculation on scatter‐corrected CBCT image: Feasibility study for adaptive proton therapy
Open Access
- 2 July 2015
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 42 (8) , 4449-4459
Abstract
Purpose: To demonstrate the feasibility of proton dose calculation on scatter‐corrected cone‐beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy.Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on‐board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x‐rays in the raw projection images: uniform scatter correction (CBCTus) and a priori CT‐based scatter correction (CBCTap). CBCT images were reconstructed using a standard FDK algorithm and GPU‐based reconstruction toolkit. Soft tissue ROI‐based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCTus, while no HU change was applied to the CBCTap. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CTref) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCTap was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images.Results: The uncorrected CBCT and CBCTus images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CTref, while the CBCTap images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCTap‐based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis.Conclusions: A priori CT‐based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.Keywords
Funding Information
- National Institutes of Health
- Elekta (Motion Management Research Grant)
- National Science Foundation
- National Institute of Health
- NCI Federal Share (C06 CA059267)
- Elekta (Motion Management Research Grant)
- National Science Foundation (NSF)
- National Institutes of Health
- NCI Federal Share (C06 CA059267)
- Elekta (Motion Management Research Grant)
- National Science Foundation
This publication has 35 references indexed in Scilit:
- Feasibility of improving cone‐beam CT number consistency using a scatter correction algorithmJournal of Applied Clinical Medical Physics, 2013
- A Fully Automated Method for CT-on-Rails-Guided Online Adaptive Planning for Prostate Cancer Intensity Modulated Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Introducing an on-line adaptive procedure for prostate image guided intensity modulate proton therapyPhysics in Medicine & Biology, 2011
- Adaptive Radiation TherapyThe Cancer Journal, 2011
- Cone Beam Computed Tomography–Derived Adaptive Radiotherapy for Radical Treatment of Esophageal CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Efficient scatter correction using asymmetric kernels2009
- Fast Monte Carlo calculation of scatter corrections for CBCT imagesJournal of Physics: Conference Series, 2008
- Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Initial experience with megavoltage (MV) CT guidance for daily prostate alignmentsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- X‐ray scatter correction algorithm for cone beam CT imagingMedical Physics, 2004