A pulsed pinhole atmospheric pressure interface for simplified mass spectrometry instrumentation with enhanced sensitivity
Authors:
- 17 March 2015
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 29 (8) , 701-706
Abstract
Rationale: A proof‐of‐concept pulsed pinhole atmospheric pressure interface, namely PP‐API, was developed and characterized for mass spectrometry instrumentation. Methods: The PP‐API was analyzed and optimized theoretically with respect to gas flow rate, opening force and dimensions. A PP‐API interfaced mass spectrometry system was then constructed and tested. Results: As a discontinuous pressure interface, the PP‐API allows efficient ion transfer from atmosphere pressure ionization sources to ion traps directly. Both nano‐ESI and APCI ionization sources have been successfully integrated with the PP‐API interface for the detection of volatile, organic, peptide and polymer samples. The use of multiple ionization sources has also been demonstrated to enhance signal intensity, as well as avoid charge competitions in ionization sources. Conclusions: With simplified geometry and high ion transfer efficiency, this PP‐API would enable miniaturized mass spectrometry systems with high sensitivity. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
Funding Information
- NNSF China (21205005, 21475010)
- MOST instrumentation program of China (2011YQ0900502, 2012YQ040140-07)
This publication has 39 references indexed in Scilit:
- Multinozzle Emitter Arrays for Nanoelectrospray Mass SpectrometryAnalytical Chemistry, 2011
- Study of Discontinuous Atmospheric Pressure Interfaces for Mass Spectrometry Instrumentation DevelopmentAnalytical Chemistry, 2010
- Ion trap mass analysis at high pressure: an experimental characterizationJournal of Mass Spectrometry, 2009
- A novel fourier transform ion cyclotron resonance mass spectrometer with improved ion trapping and detection capabilitiesJournal of the American Society for Mass Spectrometry, 2009
- Nanoelectrospray Emitter Arrays Providing Interemitter Electric Field UniformityAnalytical Chemistry, 2008
- Capillary-Based Multi Nanoelectrospray Emitters: Improvements in Ion Transmission Efficiency and Implementation with Capillary Reversed-Phase LC-ESI-MSAnalytical Chemistry, 2007
- Peer Reviewed: Atmospheric Pressure MALDIAnalytical Chemistry, 2002
- Analytical Properties of the Nanoelectrospray Ion SourceAnalytical Chemistry, 1996
- Two-laser photoionization supersonic jet mass spectrometry of aromatic moleculesAnalytical Chemistry, 1988
- Electrospray ion source. Another variation on the free-jet themeThe Journal of Physical Chemistry, 1984