Feasibility study of YSO/SiPM based detectors for virtual monochromatic image synthesis
Authors:
- 28 September 2024
- journal article
- research article
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. Preprint (Preprint) , 1-21
Abstract
BACKGROUND: The development of photon-counting CT systems has focused on semiconductor detectors like cadmium zinc telluride (CZT) and cadmium telluride (CdTe). However, these detectors face high costs and charge-sharing issues, distorting the energy spectrum. Indirect detection using Yttrium Orthosilicate (YSO) scintillators with silicon photomultiplier (SiPM) offers a cost-effective alternative with high detection efficiency, low dark count rate, and high sensor gain. OBJECTIVE: This work aims to demonstrate the feasibility of the YSO/SiPM detector (DexScanner L103) based on the Multi-Voltage Threshold (MVT) sampling method as a photon-counting CT detector by evaluating the synthesis error of virtual monochromatic images. METHODS: In this study, we developed a proof-of-concept benchtop photon-counting CT system, and employed a direct method for empirical virtual monochromatic image synthesis (EVMIS) by polynomial fitting under the principle of least square deviation without X-ray spectral information. The accuracy of the empirical energy calibration techniques was evaluated by comparing the reconstructed and actual attenuation coefficients of calibration and test materials using mean relative error (MRE) and mean square error (MSE). RESULTS: In dual-material imaging experiments, the overall average synthesis error for three monoenergetic images of distinct materials is 2.53% ±2.43%. Similarly, in K-edge imaging experiments encompassing four materials, the overall average synthesis error for three monoenergetic images is 4.04% ±2.63%. In rat biological soft-tissue imaging experiments, we further predicted the densities of various rat tissues as follows: bone density is 1.41±0.07 g/cm3, adipose tissue density is 0.91±0.06 g/cm3, heart tissue density is 1.09±0.04 g/cm3, and lung tissue density is 0.32±0.07 g/cm3. Those results showed that the reconstructed virtual monochromatic images had good conformance for each material. CONCLUSION: This study indicates the SiPM-based photon-counting detector could be used for monochromatic image synthesis and is a promising method for developing spectral computed tomography systems.Keywords
This publication has 52 references indexed in Scilit:
- Multi-voltage threshold digitizer using a time-varied threshold for photon-counting X-ray security inspection imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- Comparison of Strategies to Conserve Iodinated Intravascular Contrast Media for Computed Tomography During a ShortageJAMA, 2022
- Silicon photomultiplier‐based scintillation detectors for photon‐counting CT: A feasibility studyMedical Physics, 2021
- Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometryNuclear Engineering and Technology, 2020
- X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effectsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Photoinduced electron transfer between flavin and tryptophan in a poly(vinyl alcohol) filmDyes and Pigments, 2015
- Development of an energy-binned photon-counting detector for X-ray and gamma-ray imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Dual- and multi-energy CT: approach to functional imagingInsights into Imaging, 2011
- Material differentiation by dual energy CT: initial experienceEuropean Radiology, 2006
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005