Clinical Outcomes of 0.018-Inch and 0.022-Inch Bracket Slot Using the ABO Objective Grading System
- 1 May 2010
- journal article
- research article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 80 (3) , 528-532
Abstract
Objective: To determine if there is a significant difference in the clinical outcomes of cases treated with 0.018-inch brackets vs 0.022-inch brackets according to the American Board of Orthodontics (ABO) Objective Grading System (OGS). Materials and Methods: Treatment time and the ABO-OGS standards in alignment/rotations, marginal ridges, buccolingual inclination, overjet, occlusal relationships, occlusal contacts, interproximal contacts, and root angulations were used to compare clinical outcomes between a series of 828 consecutively completed orthodontic cases (2005–2008) treated in a university graduate orthodontic clinic with 0.018-inch- and 0.022-inch-slot brackets. Results: A two-sample t-test showed a significantly shorter treatment time and lower ABO-OGS score in four categories (alignment/rotations, marginal ridges, overjet, and root angulations), as well as lower total ABO-OGS total score, with the 0.018-inch brackets. The ANCOVA—adjusting for covariants of discrepancy index, age, gender, and treatment time—showed that the 0.018-inch brackets scored significantly lower than the 0.022-inch brackets in both the alignment/rotations category and total ABO-OGS score. Conclusions: There were statistically, but not clinically, significant differences in treatment times and in total ABO-OGS scores in favor of 0.018-inch brackets as compared with the 0.022-inch brackets in a university graduate orthodontic clinic (2005–2008).Keywords
This publication has 7 references indexed in Scilit:
- Treatment complexity index for assessing the relationship of treatment duration and outcomes in a graduate orthodontics clinicAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- The ABO discrepancy index: a measure of case complexityAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- Benefits and rationale of differential bracket slot sizes: the use of 0.018-inch and 0.022-inch slot sizes within a single bracket system.2002
- Orthodontic slot size: it's time to retool.2001
- The duration of fixed orthodontic treatment: a comparison of two groups of patients treated using Edgewise brackets with 0.018” and 0.022” slotsAustralasian Orthodontic Journal, 2000
- Objective grading system for dental casts and panoramic radiographsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1998
- Efficiency of multi‐strand steel, superelastic Ni‐Ti and ion‐implanted Ni‐Ti archwires for initial alignmentClinical Orthodontics and Research, 1998