Resolution-invariant measurements of small objects in polychromatic CT data
Author:
- 10 September 2019
- conference paper
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11113, 111130B
Abstract
Features such as particles, pores, or cracks are challenging to measure accurately in CT data when they are small relative to the data resolution, characterized as a point-spread function (PSF). These challenges are particularly acute when paired with segmentation, as the PSF distributes some of the signal from a voxel among neighboring ones; effectively dispersing some of the signal from a given object to a region outside of it. Any feature of interest with one or more dimensions on the order of the PSF will be impacted by this effect, and measurements based on global thresholds necessarily fail. Measurements of the same features should be consistent across different instruments and data resolutions. The PVB (partial volume and blurring) method successfully compensates by quantifying features that are small in all three dimensions based on their attenuation anomaly. By calibrating the CT number of the phase of interest (in this case, gold) it is possible to accurately measure particles down to <6 voxels in data acquired on two instruments, 14 years apart, despite severe artifacts. Altogether, the PVB method is accurate, reproducible, resolution-invariant, and objective; it is also notable for its favorable error structure. The principal challenge is the need for representative effective CT numbers, which reflect not only the features of interest themselves, but also the X-ray spectrum, the size, shape and composition of the enclosing sample, and processing details such as beam-hardening correction. Empirical calibration is the most effective approach.Keywords
This publication has 16 references indexed in Scilit:
- Characterizing, measuring, and utilizing the resolution of CT imagery for improved quantification of fine-scale featuresNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2014
- Imaging the femoral cortex: Thickness, density and mass from clinical CTMedical Image Analysis, 2012
- High resolution cortical bone thickness measurement from clinical CT dataMedical Image Analysis, 2010
- Computational methods for quantitative analysis of three-dimensional features in geological specimensGeosphere, 2005
- Using X-ray computed tomography in hydrology: systems, resolutions, and limitationsJournal of Hydrology, 2002
- Quantitative 3D‐fracture analysis by means of microfocus X‐Ray Computer Tomography (µCT): An example from coalGeophysical Research Letters, 2001
- Acquisition, optimization and interpretation of X-ray computed tomographic imagery: applications to the geosciencesComputers & Geosciences, 2001
- High resolution, non-destructive measurement and characterization of fracture aperturesInternational Journal of Rock Mechanics and Mining Sciences, 1998
- Nondestructive measurements of fracture aperture in crystalline rock cores using X ray computed tomographyJournal of Geophysical Research, 1993
- Correction for beam hardening in computed tomographyPhysics in Medicine & Biology, 1979