Protection Filter–Related Events in Extracranial Carotid Artery Stenting:A Single-Center Experience
Authors:
- 1 December 2006
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (6) , 711-722
Abstract
Purpose: To report the complications, rescue procedures, and consequences related to the use of an embolus protection filter during carotid artery stenting (CAS). Methods: A retrospective review was undertaken of 72 patients (58 men; mean age 70.0±8.2 years, range 56–87) with extracranial atherosclerotic carotid stenosis who underwent 77 CAS procedures under filter protection. Filter-related events and rescue procedures according to each procedural step were retrospectively evaluated on CAS angiograms. In addition, neurological events and outcomes were also assessed. Results: CAS using a filter was successful in 99% of cases, and the overall rate of minor stroke (n=1), major stroke (0), or mortality (n=1) was 2.6% at 30 days. Filter placement was successful in all cases. However, arterial tortuosity made it difficult for a filter to pass through the stenosis in 1 case; this was overcome with an additional supportive wire (0.018-inch). Filter-related events were flow impairment in 6 (7.8%), filter wedging in the catheter tip in 4 (5.2%), vasospasm >50% narrowing in 7 (9.1%), filling defects within the filter membrane in 5 (6.5%), retrieval failure with the provided retriever in 3 (3.9%), and insecure retrieval without filter collapse in 2 (2.6%). Flow impairment caused drowsy mentality and impaired verbal response in 4, which resolved after prompt filter retrieval. All the cases of filter wedging were resolved with a catheter pulled down into the stented segment to separate the filter element from the catheter tip. Significant vasospasm and filling defects were spontaneously resolved in all cases after filter retrieval. Inability to pass a retriever catheter through a stent was overcome with curved 5-F catheter manipulation in all 3 cases. Conclusion: The use of a filter during CAS may induce various angiographic or technical events at each step. For a severely stenotic and tortuous carotid lesion with difficult access, a filter may become trapped or irretrievable during flow arrest. Physicians should be aware of the preventive and rescue maneuvers to counter filter-related events, perhaps even considering another type of protection mechanism or carotid endarterectomy.Keywords
This publication has 14 references indexed in Scilit:
- Protected carotid stenting in high-surgical-risk patients: The ARCHeR resultsJournal of Vascular Surgery, 2006
- Protected Carotid-Artery Stenting versus Endarterectomy in High-Risk PatientsNew England Journal of Medicine, 2004
- Routine use of cerebral protection during carotid artery stenting: results of a multicenter registry of 753 patientsThe American Journal of Medicine, 2004
- Carotid Angioplasty and Stenting With and Without Cerebral ProtectionStroke, 2004
- Approaches to difficult filter retrieval in carotid stentingCatheterization and Cardiovascular Interventions, 2004
- Protected Carotid StentingStroke, 2003
- Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection DevicesStroke, 2003
- Initial experience with cerebral protection devices to prevent embolization during carotid artery stentingJournal of Vascular Surgery, 2002
- Retinal embolization during carotid angioplasty and stenting: Mechanisms and role of cerebral protection systemsCatheterization and Cardiovascular Interventions, 2002
- Use of the Parodi Anti-Embolism System in Carotid Stenting:Italian Trial ResultsJournal of Endovascular Therapy, 2002