Quantitative Evaluation of Segmentation- and Atlas-Based Attenuation Correction for PET/MR on Pediatric Patients
Authors:
Open Access
- 7 May 2015
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 56 (7) , 1067-1074
Abstract
Pediatric imaging is regarded as a key application for combined PET/MRI systems. As existing MR-based attenuation correction (MRAC) methods were not designed specifically for pediatric patients, we assessed the impact of 2 potentially influential factors: inter- and intra-patient variability of attenuation coefficients and anatomical variability. Furthermore, we evaluated the quantification accuracy of 3 methods for MRAC without (SEGbase) and with bone prediction using an adult/pediatric atlas (SEGwBONEad/pe) on PET data of pediatric patients. Materials: Variability of attenuation coefficients between and within pediatric (5-17y, n = 17) and adult (27-66y, n = 16) patient collectives was assessed on volumes of interest (VOIs) in CT datasets for different tissue types. Anatomical variability was assessed on SEGwBONEad/pe attenuation maps by computing mean differences to CT-based attenuation maps for regions of bone tissue, lungs and soft tissue. PET quantification was evaluated on VOIs with physiological uptake and on 80%-isocontour VOIs with elevated uptake in thorax and abdomen/pelvis. Inter- and intra-patient variability of the bias was assessed for each VOI group and method. Results: Statistically significant differences in mean VOI Hounsfield unit values between adult and pediatric collectives were found in lungs and femur. Prediction of attenuation maps using the pediatric atlas showed a reduced error in bone tissue and better delineation of bone structure. Evaluation of PET quantification accuracy showed statistically significant mean errors in mean standardized uptake values of -14%±5%/-23%±6% in bone marrow/femur-adjacent VOIs with physiological uptake for SEGbase, which could be reduced to 0%±4%/-1%±5% using SEGwBONEpe attenuation maps. Bias in soft tissue VOIs was Conclusion: Use of a dedicated atlas for the pediatric patient collective resulted in improved attenuation map prediction in osseous regions and reduced inter-patient bias variation in femur-adjacent VOIs. For the lungs, where intra-patient variation was higher for the pediatric collective, a patient- or group-specific attenuation coefficient could improve attenuation map accuracy. Mean errors of -14%/-23% in bone marrow/femur-adjacent VOIs can affect PET quantification in these regions when bone tissue is ignored.Keywords
This publication has 18 references indexed in Scilit:
- Performance of Whole-Body Integrated 18F-FDG PET/MR in Comparison to PET/CT for Evaluation of Malignant Bone LesionsJournal of Nuclear Medicine, 2013
- MR-Based Attenuation Correction Methods for Improved PET Quantification in Lesions Within Bone and Susceptibility Artifact RegionsJournal of Nuclear Medicine, 2013
- Summary Report of the First International Workshop on PET/MR Imaging, March 19–23, 2012, Tübingen, GermanyMolecular Imaging and Biology, 2013
- Diagnostic value of combined 18F-FDG PET/MRI for staging and restaging in paediatric oncologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012
- Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRIJournal of Nuclear Medicine, 2012
- MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based MethodsJournal of Nuclear Medicine, 2011
- elastix: A Toolbox for Intensity-Based Medical Image RegistrationIEEE Transactions on Medical Imaging, 2009
- Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT DataJournal of Nuclear Medicine, 2009
- Analysis of Proximal Femur DXA Scans in Growing Children: Comparisons of Different Protocols for Cross-Sectional 8-Month and 7-Year Longitudinal DataJournal of Bone and Mineral Research, 2000
- Computed Tomographic Lung Density in ChildrenInvestigative Radiology, 1987