Analysis strategies for time-resolved X-ray solution scattering at high repetition rate XFEL sources
Open Access
- 1 January 2026
- journal article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (1) , 18-31
Abstract
With the start of the user program at the European XFEL in 2017, and more recently with the LCLS-II upgrade, the X-ray repetition rate at X-ray free-electron lasers (XFELs) has been pushed into the kilo- and megahertz regimes. These high X-ray repetition rates provide an increase in the integrated flux at these facilities by orders of magnitude, potentially facilitating measurements that were previously infeasible due to signal-to-noise constraints. However, the high repetition rates lead to new challenges for sample delivery and a shorter time for the sample to recover between X-ray pulses. For solution-phase techniques, the X-ray–sample interactions will strongly perturb or even vaporize the sample jet. Although the sample can be replenished, up to X-ray repetition rates of ∼100 kHz, by flowing the jet at high speeds, this does not completely mitigate the jet perturbations. In this work, we present a characterization of the jet perturbations induced by the high X-ray repetition rates at the European XFEL. We show how these can introduce background signals in time-resolved X-ray solution scattering data measured at the Femtosecond X-ray Experiments (FXE) instrument. We show that it is possible to mitigate these experimental artifacts by employing an alternating excitation scheme combined with careful background subtraction and that implementing this approach in the experimental design outperforms more simple background subtraction schemes. The methodology, the observations and analysis results are discussed in relation to the evolving landscape of XFEL sources.Keywords
Funding Information
- Novo Nordisk Fonden (NNF20OC0061740)
- Natur og Univers, Det Frie Forskningsråd (DFF-1127-00382B)
- DanScatt
- HORIZON EUROPE European Research Council (101166044)
This publication has 49 references indexed in Scilit:
- Disentangling detector data in XFEL studies of temporally resolved solution state chemistryFaraday Discussions, 2015
- Singular value decomposition as a tool for background corrections in time-resolved XFEL scattering dataPhilosophical Transactions of the Royal Society B: Biological Sciences, 2014
- Singlet exciton fission in solutionNature Chemistry, 2013
- Introducing a standard method for experimental determination of the solvent response in laser pump, X-ray probe time-resolved wide-angle X-ray scattering experiments on systems in solutionPhysical Chemistry Chemical Physics, 2013
- Benchmark oxygen-oxygen pair-distribution function of ambient water from x-ray diffraction measurements with a wide Q-rangeThe Journal of Chemical Physics, 2013
- Guest–Host Interactions Investigated by Time-Resolved X-ray Spectroscopies and Scattering at MHz Rates: Solvation Dynamics and Photoinduced Spin Transition in Aqueous Fe(bipy)32+The Journal of Physical Chemistry A, 2012
- Analysis of time-resolved X-ray scattering data from solution-state systemsActa Crystallographica Section A Foundations of Crystallography, 2010
- Visualizing Solution-Phase Reaction Dynamics with Time-Resolved X-ray LiquidographyAccounts of Chemical Research, 2008
- Impulsive solvent heating probed by picosecond x-ray diffractionThe Journal of Chemical Physics, 2006
- Deconvolutions based on singular value decomposition and the pseudoinverse: a guide for beginnersJournal of Biochemical and Biophysical Methods, 1994