High-Throughput Liquid Chromatography/Mass Spectrometry Method for the Determination of the Chromatographic Hydrophobicity Index
Authors:
- 6 July 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (15) , 3716-3722
Abstract
A fast gradient reversed-phase liquid chromatography (LC) method, using an acetonitrile gradient was developed to determine the chromatographic hydrophobicity index (CHI), as reported by Valco et al. (Anal. Chem. 1997, 69, 2022−2029).The analytical method provides retention times, based on UV detection at two different wavelengths, which then are converted into CHI values after calibration with a set of test compounds. The CHI of each compound is measured at three different pH values, 2.0, 7.4, and 10.5; so using an 8-min gradient at each pH value one compound can be analyzed in ∼24 min. The aim of this work is to improve the throughput of the CHI screening using a LC/MS approach, so the application of the LC/MS technique is an extension of the LC/UV approach previously reported by Valco et al. This approach allows contemporary injection of N compounds into the LC/MS system, the retention time of each compound can be then extracted from the selected ion recording chromatograms. The throughput of the existing screening method could be increased by N times, where N is the number of compounds injected, so only three runs are needed to determine the CHI at three different pH values for a set of N compounds. The highest value of N depends on the total number of channels that can be monitored simultaneously; in the present work, 32 channels were used. This LC/MS method has been tested for a number of commercial products analyzed as mixtures, and data obtained were compared with those coming from the classical LC/UV approach. In the same way, the method was tested for a number of compounds associated with two GlaxoWellcome projects in the antibacterial area. Data reported show that the LC/MS method can be successfully applied for analyzing compounds in mixtures and for compounds with poor UV absorption, which cannot be analyzed with the standard LC/UV method.Keywords
This publication has 17 references indexed in Scilit:
- Peer Reviewed: Combinatorial ChemistryAnalytical Chemistry, 1998
- Chromatographic Hydrophobicity Index by Fast-Gradient RP-HPLC: A High-Throughput Alternative to log P/log DAnalytical Chemistry, 1997
- Methods for determiningn-octanol-water partition constantsTrAC Trends in Analytical Chemistry, 1996
- Improved method for estimating water solubility from octanol/water partition coefficientEnvironmental Toxicology and Chemistry, 1996
- Applications of Combinatorial Technologies to Drug Discovery. 1. Background and Peptide Combinatorial LibrariesJournal of Medicinal Chemistry, 1994
- Simple Procedure for Determining Octanol–Aqueous Partition, Distribution, and Ionization Coefficients by Reversed-Phase High-Pressure Liquid ChromatographyJournal of Pharmaceutical Sciences, 1978
- Use of high-pressure liquid chromatography for quantitative structure-activity relationship studies of sulfonamides and barbituratesJournal of Medicinal Chemistry, 1976
- Quantitative approach to biochemical structure-activity relationshipsAccounts of Chemical Research, 1969
- Deoxyribonucleoside-3′,5′ Cyclic Phosphates. Synthesis and Acid-Catalyzed and Enzymic HydrolysisJournal of the American Chemical Society, 1964
- Correlation of Biological Activity of Phenoxyacetic Acids with Hammett Substituent Constants and Partition CoefficientsNature, 1962