Comparison of ISO Standard and TKR patient axial force profiles during the stance phase of gait
Authors:
- 20 December 2011
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 226 (3) , 227-234
Abstract
Preclinical endurance testing of total knee replacements (TKRs) is performed using International Organization for Standardization (ISO) load and motion protocols. The standards are based on data from normal subjects and may not sufficiently mimic in vivo implant conditions. In this study, a mathematical model was used to calculate the axial force profile of 30 TKR patients with two current implant types, 22 with NexGen and eight with Miller-Galante II Cruciate-Retaining TKRs, and statistically compare the axial force specified by the ISO standard to the TKR patients. Significant differences were found between the axial forces of both groups of TKR patients and the ISO standard at local maxima and minima points in the first half of stance. The force impulse (area under the axial force curve, representing cumulative loading) was smaller for the ISO standard than the TKR patients, but only for those with NexGen implants. Waveform analysis using the coefficient of multiple correlation showed that the ISO and TKR patient axial force profiles were similar. The combined effect of ISO standard compressive load and motion differences from TKR patients could explain some of the differences between the wear scars on retrieved tibial components and those tested in total joint simulators.Keywords
This publication has 27 references indexed in Scilit:
- Direct comparison of measured and calculated total knee replacement force envelopes during walking in the presence of normal and abnormal gait patternsJournal of Biomechanics, 2012
- Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: A comparison with the displacement-controlled ISO standardJournal of Biomechanics, 2009
- Comparison of polyethylene tibial insert damage from in vivo function and in vitro wear simulationJournal of Orthopaedic Research, 2009
- A parametric approach to numerical modeling of TKR contact forcesJournal of Biomechanics, 2009
- The Mark Coventry Award: In Vivo Knee Forces During Recreation and Exercise After Knee ArthroplastyClinical Orthopaedics and Related Research, 2008
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Effects of knee simulator loading and alignment variability on predicted implant mechanics: A probabilistic studyJournal of Orthopaedic Research, 2006
- Changing Demographics of Patients with Total Joint ReplacementClinical Orthopaedics and Related Research, 2006
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Tractive forces during rolling motion of the knee: Implications for wear in total knee replacementJournal of Biomechanics, 1997