Abstract
Supervised cable-force anomaly detection requires labeled damage data that are rarely available for in-service bridges. This study therefore proposes an unsupervised convolutional autoencoder (CAE) that identifies cable-force anomalies from bridge-deck vibration signals. Finite-element simulations provide training data, and the CAE learns only healthy-state vibration patterns. Reconstruction quality is evaluated using three complementary indices: reconstruction error (ERROR), structural similarity (SSIM), and the original-to-reconstructed signal ratio (ORSR). Extreme value theory provides reproducible unsupervised thresholds, while clustering reveals the progression of cable-force loss. The method was validated using a scaled model of the First Zhongshan Bridge and a full-scale cable-stayed bridge. The three indices distinguished normal and abnormal states and exhibited progressive changes with increasing cable-force loss, demonstrating the feasibility of deck-vibration-based cable-force anomaly identification.
Funding Information
  • Guangdong Province Science and Technology Department under the International Collaboration Program (2023A0505050094)

This publication has 34 references indexed in Scilit: