Coefficients of Local Head Losses in Steady-State Flow of Throttled Surge Tanks with Standpipe by CFD
Authors:
- 25 March 2013
- journal article
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 677, 290-295
Abstract
This study investigates the steady-state flow pattern of throttled surge tanks with standpipe, especially the coefficients of local head losses. The experiments were carried out, and FLUENT, which solves the Reynolds-averaged Navier-Stokes equations, was applied to experimental data for solving flow fields. The results show the computed and measured local head losses agree closely. The coefficients of the local head losses are linearly proportional to diameter ratio with the slope of 0.037. The anticlockwise backflow region occurs in the standpipe, and it induces inflow into and outflow from the standpipe. For hydraulic engineering projects, the discharge into and out from standpipe does not change with velocity and diameter of main conduit, but are linearly proportional to diameter ratio with the slope of 0.0378.Keywords
This publication has 3 references indexed in Scilit:
- A new k-ϵ eddy viscosity model for high reynolds number turbulent flowsComputers & Fluids, 1995
- Performance Prediction by Viscous Flow Analysis for Francis Turbine RunnerJournal of Fluids Engineering, 1994
- The numerical computation of turbulent flowsComputer Methods in Applied Mechanics and Engineering, 1974