Computer-aided Classification of BI-RADS Category 3 Breast Lesions
Authors:
- Shalom S. BuchbinderSBShalom S. Buchbinder
- Isaac S. LeichterILIsaac S. Leichter
- Richard B. LedermanRLRichard B. Lederman
- Boris NovakBNBoris Novak
- Philippe N. BambergerPBPhilippe N. Bamberger
- Miryam Sklair-LevyMSMiryam Sklair-Levy
- Gail YarmishGYGail Yarmish
- Scott I. FieldsSFScott I. Fields
- 1 March 2004
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (3) , 820-823
Abstract
To evaluate a system for computer-aided classification (CAC) of lesions assigned to Breast Imaging Reporting and Data System (BI-RADS) category 3 at conventional mammographic interpretation. A CAC system was used to analyze 106 cases of lesions (42 malignant) that at blinded retrospective interpretation were assigned to BI-RADS category 3 by at least two of four radiologists. The CAC system automatically extracted from the digitized mammograms quantitative features that characterized the lesions. The system then used a classification scheme to score the lesions by the likelihood of their malignancy on the basis of these features. The classification scheme was trained with 646 pathologically proved cases (323 malignant), and the results were tested with receiver operating characteristic (ROC) analysis by using the jackknife method. Sensitivity, specificity, positive predictive value, and accuracy were calculated. Category 3 lesions were stratified among BI-RADS categories 2-5 according to CAC-assigned lesion score, and this classification was compared with the results of pathologic analysis. Jackknife analysis of CAC results in the training data set yielded a sensitivity of 94%, specificity of 78%, positive predictive value of 81%, and area under the ROC curve of 0.90. Of the 42 malignant lesions that had been classified at conventional interpretation as probably benign, nine were assigned by the CAC system to BI-RADS category 4, and 29 were assigned to category 5. The CAC system correctly upgraded the BI-RADS classification of these 38 lesions (sensitivity, 90%) and incorrectly upgraded the classification of only 20 benign lesions (specificity, 69%). The CAC system scored 38 of the 42 malignant lesions initially assigned to BI-RADS category 3 as BI-RADS category 4 or 5, and thus correctly upgraded the category in 90% of these lesions.Keywords
This publication has 16 references indexed in Scilit:
- Six-month Follow-up: An Alternative ViewRadiology, 1999
- Commentary on Dr Rubin's ViewpointRadiology, 1999
- Probably Benign Breast Lesions: When Should Follow-up Be Recommended and What Is the Optimal Follow-up Protocol?Radiology, 1999
- Commentary on Dr Sickles's ViewpointRadiology, 1999
- Coding mammograms using the classification "probably benign finding--short interval follow-up suggested".American Journal of Roentgenology, 1999
- Short-interval follow-up mammography versus immediate core biopsy of benign breast lesions: assessment of patient stress.American Journal of Roentgenology, 1998
- Analysis of spiculation in the computerized classification of mammographic massesMedical Physics, 1995
- Needle core biopsy guided with mammography: a study of cost-effectiveness.Radiology, 1994
- Nonpalpable, probably benign lesions: role of follow-up mammography.Radiology, 1992
- Periodic mammographic follow-up of probably benign lesions: results in 3,184 consecutive cases.Radiology, 1991