Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
Open Access
- 16 December 2024
- journal article
- research article
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-9
Abstract
Background: In recent times, size-specific dose estimate (SSDE) has been the ideal metric for accurate estimation of individual patient doses in computed tomography (CT) examinations. The objective of this study was to estimate patient radiation doses based on SSDE and the water-equivalent diameter (DW) as an effect tool for dose optimization in paediatric head CT at two facilities in Tamale Metropolis, in the northern region of Ghana. This is a preliminary retrospective study conducted on 57 paediatric patients (comprising 32 males and 25 females), aged newborns to 16 years old, who underwent head CT examinations. Patient head sizes were determined in terms DW, which was calculated by manual contouring the circumference of the CT images excluding the background to measure the region of interest (ROI) using the mid-slice axial CT images. SSDE was calculated as the product of CTDIvol and the size-specific conversion coefficients (CTDIvol, 16 to SSDE) obtained from the American Association of Physicists in Medicine (AAPM) Report 293. Results: At facility ‘A’, the median SSDE values for patients, aged 3 months to 1 year, 1 to 6 years, and older than 6 years were 46.1 mGy, 39.6 mGy, and 48.2 mGy, respectively. The corresponding CTDIvol values were 42.3 mGy, 39.1 mGy, and 51.7 mGy. Facility ‘B’ reported median SSDE values of 36.0, 39.2, and 43.8 mGy, with corresponding CTDIvol values of 28.7, 39.8, and 46.9 mGy for the same age categories. For all age groups, the two facilities showed significant differences in SSDE values (44.72 mGy vs. 39.77 mGy, p = 0.009) and CTDIvol values (45.72 mGy vs. 40.60 mGy, p = 0.03). Some of the age group doses were up to 25.3% in CTDIvol and 25.8% in SSDE higher than those found in published data. Conclusions: The SSDEs estimated showed significant variations between the two facilities, indicating a possible variability of scan protocols for paediatric head CT examinations. The SSDEs obtained in this study could be useful for optimization of paediatric routine head CT examinations.Keywords
This publication has 23 references indexed in Scilit:
- Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adultsNature Medicine, 2023
- SIZE-SPECIFIC DOSE ESTIMATES FOR PEDIATRIC NON-CONTRAST HEAD CT SCANS: A RETROSPECTIVE PATIENT STUDY IN TUNJA, COLOMBIARadiation Protection Dosimetry, 2021
- Understanding, justifying, and optimizing radiation exposure for CT imaging in nephrourologyNature Reviews Urology, 2019
- PATIENTS DOSE ESTIMATION IN CT EXAMINATIONS USING SIZE SPECIFIC DOSE ESTIMATESRadiation Protection Dosimetry, 2018
- Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimatesJournal of Radiological Protection, 2018
- Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE)La radiologia medica, 2018
- Local diagnostic reference level based on size-specific dose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children’s hospitalPediatric Radiology, 2014
- Automated Pediatric Abdominal Effective Diameter Measurements Versus Age-Predicted Body Size for Normalization of CT DoseJournal of Digital Imaging, 2013
- ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional RadiologyAnnals of the ICRP, 2013
- Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort studyThe Lancet, 2012