Early and Late Efficacy of Three Types of Transvenous Atrial Leads
Authors:
- 1 March 1984
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 7 (2) , 195-202
Abstract
Experience with three transvenous atrial leads, representing different principles, is presented. The types were screw‐in (Vitatron Helifix‐12), J‐lead (Intermedics Lifeline 483–01) and straight‐tined (Medtronic 6961). The study comprised insertion of 86 leads (30 Helifix, 40 Lifeline, 16 Medtronic) in 76 patients. Atrial fibrillation occurred during insertion in two patients, and in two others stable electrode positioning in the right atrial appendage was not achieved. Stable position and acceptable intracardiac P‐waves were obtained in all the other patients (in 5 after change to another type of lead). Atrial triggered ventricular pacing was used in 34 cases and atrial pacing was used in 38. The P‐wave amplitude at insertion was significantly less with Helifix than with Lifeline or Medtronic. The stimulation thresholds (range 0.25–2.5 V) did not differ significantly between the electrodes. Dislodgement of the electrode occurred during the first week in seven cases (5 Lifeline, 2 Helifix), but no late dislodgement occurred. The mean follow‐up was 14 months (range 1–31). All three atrial leads offer acceptable function with regard to electrophysiological properties and electrode stability.Keywords
This publication has 20 references indexed in Scilit:
- Modern atrial and ventricular leads for permanent cardiac pacing.Heart, 1981
- Permanent Atrial LeadsPacing and Clinical Electrophysiology, 1980
- A New Lead for Transvenous Atrial Pacing and Sensing Clinical and Electrophysiological ExperiencesPacing and Clinical Electrophysiology, 1980
- The Small‐Tined Pacemaker Lead—Absence of DislodgementPacing and Clinical Electrophysiology, 1980
- Clinical and electrophysiological characteristics of a transvenous atrial lead.Heart, 1979
- Early malfunction of transvenous pacemaker electrodes. A three-center study.Circulation, 1979
- Preliminary Experience with the Helifix Electrode for Transvenous Atrial ImplantationPacing and Clinical Electrophysiology, 1979
- Detector electrode introduced by mediastinoscopy for atrial triggered cardiac pacing. A follow-up of electrode function in 82 patients.Heart, 1977
- Clinical use of a new transvenous atrial leadThe American Journal of Cardiology, 1977
- Diagnostic and Therapeutic Uses of Atrial PacingCirculation, 1971