Objective: To evaluate and compare magnetic sphincter augmentation (MSA) device sizing protocols on postoperative outcomes and dysphagia. Background: Among predictors of dysphagia after MSA, device size is the only factor that may be modified. Many centers have adopted protocols to increase device size. However, there are limited data on the impact of MSA device upsizing protocols on surgical outcomes. Methods: Patients who underwent MSA were implanted with 2 or 3 beads above the sizing device’s pop-off point (POP). Clinical and objective outcomes >1 year after surgery were compared between patients implanted with POP+2-versus-POP+3 sizing protocols. Multiple subgroups were analyzed for the benefit of upsizing. Preoperative and postoperative characteristics were compared between the size patients received, regardless of protocol. Results: A total of 388 patients were implanted under POP+2 and 216 under POP+3. At a mean of 14.2 (7.9) months, pH normalization was 73.6% and 34.1% required dilation, 15.9% developed persistent dysphagia, and 4.0% required removal. The sizing protocol had no impact on persistent dysphagia (P=0.908), pH normalization (P=0.822), or need for dilation (P=0.210) or removal (P=0.191). Subgroup analysis found that upsizing reduced dysphagia in patients with 5000 (0% vs 30.4%, P=0.034). Regardless of sizing protocol, as device size increased there was a stepwise increase in the percent male sex (P30 (P3 cm (PPPPP=0.043) or removal (P=0.014). Conclusions: Upsizing from POP+2 to POP+3 does not reduce dysphagia or affect other MSA outcomes; however, patients with poor peristalsis or hypercontractile esophagus do benefit. Regardless of sizing protocol, preoperative clinical characteristics varied among device sizes, suggesting size is not a modifiable factor, but a surrogate for esophageal circumference.Keywords
This publication has 20 references indexed in Scilit:
- Removing the magnetic sphincter augmentation device: operative management and outcomesSurgical Endoscopy, 2018
- Worldwide Experience with Erosion of the Magnetic Sphincter Augmentation DeviceJournal of Gastrointestinal Surgery, 2018
- Laparoscopic Magnetic Sphincter Augmentation vs Laparoscopic Nissen Fundoplication: A Matched-Pair Analysis of 100 PatientsJournal of the American College of Surgeons, 2015
- Magnetic sphincter augmentation and fundoplication for GERD in clinical practice: one-year results of a multicenter, prospective observational studySurgical Endoscopy, 2014
- Esophageal Sphincter Device for Gastroesophageal Reflux DiseaseNew England Journal of Medicine, 2013
- Laparoscopic Sphincter Augmentation Device Eliminates Reflux Symptoms and Normalizes Esophageal Acid ExposureAnnals of Surgery, 2010
- Use of a magnetic sphincter for the treatment of GERD: a feasibility studyGastrointestinal Endoscopy, 2008
- Medical Devices in Orthopedic ApplicationsToxicologic Pathology, 2008
- The small-caliber esophagus: An unappreciated cause of dysphagia for solids in patients with eosinophilic esophagitisGastrointestinal Endoscopy, 2002
- Congenital esophageal stenosisDigestive Diseases and Sciences, 1990