Maintenance of acetabular correction following PAO: a multicenter study comparing stainless-steel and titanium screws
Open Access
- 28 February 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Hip Preservation Surgery
- Vol. 11 (2) , 140-143
Abstract
Stainless-steel screws are commonly used for fragment fixation during periacetabular osteotomy (PAO) at our institutions. Titanium is reserved for patients with documented nickel allergies. Titanium screws possess a significantly lower Young’s modulus than stainless steel and, therefore, potentially less resistance to physiologic loading. Thus, we hypothesized that the use of titanium screws might be associated with changes in acetabular correction prior to healing. The aim of this study was to compare the maintenance of acetabular correction following PAO using stainless-steel or titanium screws. A documented nickel allergy was confirmed with an allergy specialist. Patients’ age at surgery, gender and BMI were collected. The lateral center–edge angle of Wiberg (LCEA), medial center–edge angle (MCEA), anterior wall index (AWI), posterior wall index (PWI) and Tönnis angle were measured. The delta value for radiographic parameters was calculated as the difference between values immediately post-operation and at 6 months post-operation. Only age at surgery (P < 0.001) and the pre-operative LCEA (P = 0.013) were significantly different between groups ( Tables I and II). The remaining pre- and post-operative radiological measurements were similar ( Table II). Comparison of delta values at 6 months follow-up indicated no significant differences between screw types ( Table III). No patients in the titanium group had a trans-iliac retrograde screw included in their construct (P = 0.003). All patients healed from their osteotomies. The use of titanium screws in patients with an allergy to nickel was not associated with differences in acetabular correction or the rate of osseous union rates despite its lower inherent mechanical properties.Keywords
This publication has 20 references indexed in Scilit:
- Hip DysplasiaClinics in Sports Medicine, 2021
- Is a Titanium Implant for Total Knee Arthroplasty Better? A Randomized Controlled StudyThe Journal of Arthroplasty, 2021
- Complications and outcome after periacetabular osteotomy - influence of surgical approachHIP International, 2019
- Review on titanium and titanium based alloys as biomaterials for orthopaedic applicationsMaterials Science and Engineering: C, 2019
- Biomedical titanium alloys with Young’s moduli close to that of cortical boneRegenerative Biomaterials, 2016
- Early Outcomes of Titanium-Based Highly-Porous Acetabular Components in Revision Total Hip ArthroplastyThe Journal of Arthroplasty, 2015
- Titanium and zirconia particle-induced pro-inflammatory gene expression in cultured macrophages and osteolysis, inflammatory hyperalgesia and edema in vivoLife Sciences, 2014
- The response of macrophages to titanium particles is determined by macrophage polarizationActa Biomaterialia, 2013
- The Acetabular Wall Index for Assessing Anteroposterior Femoral Head Coverage in Symptomatic PatientsClinical Orthopaedics and Related Research, 2012
- Periacetabular Osteotomy for Hip PreservationOrthopedic Clinics of North America, 2012