Double Fed Induction Generator Shaft Misalignment Monitoring by FBG Frame Strain Sensing
Open Access
- 30 March 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (15) , 8541-8551
Abstract
this study explores the potential for using FBG strain sensing to enable recognition of the shaft misalignment condition in electric machine drivetrains through observation of machine frame distributed relative strain. The sensing principles, design and installation methods of the proposed technique are detailed in the paper. The scheme was applied on a purpose built wind turbine generator representative laboratory test rig and its performance evaluated in an extensive experimental study involving a range of healthy and misaligned shaft operating conditions. The obtained experimental data demonstrate the reported method’s capability to enable recognition of generator shaft misalignment conditions and thus its health monitoring. Finally, it is shown that the thermal variation of the generator frame structure inherent to its operation, combined with the FBG sensor intrinsic thermo-mechanical cross sensitivity, has no detrimental impact on the fidelity and usability of the observed strain measurements.Keywords
Funding Information
- U.K. Engineering and Physical Sciences Research Council HOME-Offshore: Holistic Operation and Maintenance for Energy from Offshore Wind Farms Consortium (EP/P009743/1)
This publication has 28 references indexed in Scilit:
- Theoretical and experimental research on turbo-generator shaft alignment using strain gauge methodJournal of Vibration and Control, 2016
- Laser based measurement for the monitoring of shaft misalignmentMeasurement, 2016
- Supply Induced Interharmonic Effects in Wound Rotor and Doubly-Fed Induction GeneratorsIEEE Transactions on Energy Conversion, 2015
- Investigation of wound rotor induction machine vibration signal under stator electrical fault conditionsThe Journal of Engineering, 2014
- Wind turbine condition monitoring: technical and commercial challengesWind Energy, 2012
- Signatures of electrical faults in the force distribution and vibration pattern of induction motorsIEE Proceedings - Electric Power Applications, 2006
- Detecting load unbalance and shaft misalignment using stator current in inverter-driven induction motors2003
- Fiber Bragg gratingsReview of Scientific Instruments, 1997
- Fiber grating spectraJournal of Lightwave Technology, 1997
- Vibration Analysis Of A Motor-Flexible Coupling-Rotor System Subject To Misalignment And Unbalance, Part I: Theoretical Model And AnalysisJournal of Sound and Vibration, 1994