Comprehensive analysis of cytokine adsorption properties of polymethyl methacrylate (PMMA) membrane material
Authors:
Open Access
- 17 March 2022
- journal article
- research article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 25 (4) , 343-349
Abstract
In acute kidney injury caused by sepsis (septic AKI), excessive production of inflammatory mediators is believed to be involved in deterioration of the disease. Renal replacement therapy using a polymethyl methacrylate (PMMA) membrane hemofilter improves the pathological condition of septic AKI by adsorbing and removing inflammatory cytokines. However, the adsorption properties of the PMMA membrane are unclear. In this study, we comprehensively analyzed the adsorption of 48 different cytokines in human plasma to PMMA and polysulfone (PS) membranes. Seventy-nine percent (38/48) of the cytokines were adsorbed more efficiently to the PMMA membrane than the PS membrane, which indicates that the PMMA membrane has high cytokine adsorption ability. The adsorption rate tended to be higher for the cytokines with lower molecular weight, and there was a significant correlation between the molecular weight of the cytokines and the adsorption rates. Electron microscopy showed that the PMMA hollow fiber membrane had a uniform internal structure from the inner to the outer layers of the membrane and had nano-pores inside the membrane that may have contributed to the adsorption of proteins with a specific molecular weight range. The clinical efficacy of a PMMA membrane hemofilter with cytokine adsorption properties against septic AKI needs further investigation including the evaluation of filtration performance of the hemofilters.Keywords
This publication has 15 references indexed in Scilit:
- Prescription of CRRT: a pathway to optimize therapyAnnals of Intensive Care, 2020
- Acute kidney injury from sepsis: current concepts, epidemiology, pathophysiology, prevention and treatmentKidney International, 2019
- Comparison of adsorption of selected antibiotics on the filters in continuous renal replacement therapy circuits: in vitro studiesJournal of Artificial Organs, 2019
- Cytokine Removal in Extracorporeal Blood Purification: An in vitro StudyBlood Purification, 2019
- Adsorption of Nafamostat Mesilate on AN69ST Membranes: A Single‐Center Retrospective and In Vitro StudyTherapeutic Apheresis and Dialysis, 2017
- AN69ST membranes adsorb nafamostat mesylate and affect the management of anticoagulant therapy: a retrospective studyJournal of Intensive Care, 2017
- Intensity of Continuous Renal-Replacement Therapy in Critically Ill PatientsNew England Journal of Medicine, 2009
- Intensity of Renal Support in Critically Ill Patients with Acute Kidney InjuryNew England Journal of Medicine, 2008
- Continuous Hemodiafiltration with PMMA Hemofilter in the Treatment of Patients with Septic ShockMolecular Medicine, 2008
- Affinity adsorption of recombinant human interferon-α on a porous dye-affinity adsorbentColloids and Surfaces A: Physicochemical and Engineering Aspects, 2004