Determination of Hg(II) ions in water samples by a novel Hg(II) sensor, based on calix[4]arene derivative
- 15 April 2009
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 89 (6) , 407-422
Abstract
A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10−6–1.0 × 10−1 M, with a Nernstian slope of 29.4 ± 0.4 mV decade−1, and a detection limit of 4.0 × 10−7 M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5–4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg2+ ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.Keywords
This publication has 29 references indexed in Scilit:
- Mercury(II) sensors based on calix[4]arene derivatives as receptor moleculesSensors and Actuators B: Chemical, 2007
- Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II)Analytica Chimica Acta, 2007
- Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) SensorBulletin of the Korean Chemical Society, 2007
- Potentiometric determination of mercury(II) using a tribromomercurate–rhodamine B PVC membrane sensorInternational Journal of Environmental Analytical Chemistry, 2006
- Selective recovery and preconcentration of mercury with a benzoylthiourea-solid supported liquid membrane systemAnalytica Chimica Acta, 2005
- Oligo(ethylenoxy)oxy‐Bridged Stilbenes as Ligands for σ‐ and π‐Coordinated Ag+ and Na+ IonsAngewandte Chemie International Edition, 1997
- Bioaccumulation of mercury and methylmercuryWater, Air, & Soil Pollution, 1995
- Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensorsAnalytica Chimica Acta, 1993
- Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriersAnalytica Chimica Acta, 1985
- A Conductance Study of 18-Crown-6 and Dibenzo-18-crown-6 Complexes with K+ in Various SolventsBulletin of the Chemical Society of Japan, 1983