Structural Performance and Strength Prediction of Steel-to-Concrete Box Girder Deck Transition Zone of Hybrid Steel-Concrete Cable-Stayed Bridges
- 1 November 2016
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 21 (11)
Abstract
Because a large longitudinal force exists in hybrid girder cable-stayed bridges due to the cable tension, its transfer mechanisms on the steel-concrete combination segment would be an important issue. In this study, experiments and theoretical analysis were conducted to characterize the longitudinal force transfer mechanisms of the steel-concrete combination segment in hybrid girder cable-stayed bridges. Five full-scale local structure specimens were designed and manufactured based on the original design of the steel-to-concrete transition zone according to a completed cable-stayed bridge in China. The specimens were subjected to monotonic loading and tested up to complete failure. The load-slip curves; stress distribution and failure modes, which varied with the thickness of the bearing plate; and the shear connector distribution were obtained. To simulate the test properly, calculation methods for predicting the shear connector capacity and corresponding load-slip curves were proposed based on t...Keywords
This publication has 22 references indexed in Scilit:
- Perforated shear connectors on composite girders under monotonic loading: An experimental approachEngineering Structures, 2013
- Evaluation of the connection efficiency of hybrid steel–concrete girder using finite element approachInternational Journal of Mechanical Sciences, 2012
- Experimental study on joint of spliced steel–PSC hybrid girder, part II: Full-scale test of spliced hybrid I-girderEngineering Structures, 2011
- Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangementJournal of Constructional Steel Research, 2010
- Finite element modeling and analysis of a hybrid steel–PSC beam connectionEngineering Structures, 2010
- Experimental evaluation of the structural response of Perfobond shear connectorsEngineering Structures, 2010
- Experimental study on inelastic mechanical behaviour of composite girders under hogging momentJournal of Constructional Steel Research, 2010
- Behavior of Headed Stud Shear Connectors in Composite BeamJournal of Structural Engineering, 2005
- Experimental study on stud shear connectors subjected to cyclic loadingJournal of Constructional Steel Research, 1996
- Push-out tests on studs in high strength and normal strength concreteJournal of Constructional Steel Research, 1996