Self-contained Position Tracking of Human Movement Using Small Inertial/Magnetic Sensor Modules
- 1 April 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 2526-2533
Abstract
Numerous applications require a self-contained personal navigation system that works in indoor and outdoor environments, does not require any infrastructure support, and is not susceptible to jamming. Posture tracking with an array of inertial/magnetic sensors attached to individual human limb segments has been successfully demonstrated. The "sourceless" nature of this technique makes possible full body posture tracking in an area of unlimited size with no supporting infrastructure. Such sensor modules contain three orthogonally mounted angular rate sensors, three orthogonal linear accelerometers and three orthogonal magnetometers. This paper describes a method for using accelerometer data combined with orientation estimates from the same modules to calculate position during walking and running. The periodic nature of these motions includes short periods of zero foot velocity when the foot is in contact with the ground. This pattern allows for precise drift error correction. Relative position is calculated through double integration of drift corrected accelerometer data. Preliminary experimental results for various types of motion including walking, side stepping, and running document accuracy of distance and position estimates.Keywords
This publication has 14 references indexed in Scilit:
- Implementation and Experimental Results of a Quaternion-Based Kalman Filter for Human Body Motion Tracking2006
- The Technology of Accelerometry-Based Activity Monitors: Current and FutureMedicine & Science in Sports & Exercise, 2005
- Assessment of Walking Features From Foot Inertial SensingIEEE Transactions on Biomedical Engineering, 2005
- Design and implementation of MARG sensors for 3-DOF orientation measurement of rigid bodies2004
- Assessment of spatio-temporal gait parameters from trunk accelerations during human walkingGait & Posture, 2003
- Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m WalkMedicine & Science in Sports & Exercise, 2003
- Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy CostMedicine & Science in Sports & Exercise, 2003
- A method for dead reckoning parameter correction in pedestrian navigation systemIEEE Transactions on Instrumentation and Measurement, 2003
- A reliable gait phase detection systemIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001
- Displacement of the pelvis during human walking: experimental data and model predictionsGait & Posture, 1997