Compartment Syndrome In Schatzker Type VI Plateau Fractures and Medial Condylar Fracture-Dislocations Treated with Temporary External Fixation
- 1 August 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 23 (7) , 502-506
Abstract
Objective: Bicondylar tibial plateau fracture with metaphyseal-diaphyseal dissociation. Schatzker VI and medial plateau fracture-dislocations are commonly treated with initial external fixation until the soft tissues allow for more definitive internal fixation. The purpose of this study was to review the incidence of compartment syndrome (CS) in these injuries and the timing of their occurrence in relation to placement of the external fixator. Design: Retrospective cohort, consecutive series. Setting: Academic level I trauma center. Patients/Participants: Over a 5-year period, 67 patients with tibial plateau fractures and fracture-dislocations were treated with initial external fixation within 48 hours of injury. There were 50 fractures (type VI) and 17 fracture-dislocations. Intervention: CS was documented prospectively, and all patients were examined for signs of missed CS during office visits. Main Outcome Measure: The timing of the CS was noted as present at presentation and diagnosis after external fixation but during the initial operative session, late, or missed. Results: Overall, there were 18 CSs (27%) in 67 extremities. CS was more common after fracture-dislocations (9 of 17) than plateau fractures (9 of 50) (P = 0.009, χ2). Most CSs were diagnosed after frame placement (10), either in the operating room at the initial session (4 of 10) or within the first 48 hours after frame placement (3 of 10). There were 3 delayed cases diagnosed after the CS had run its course. All 3 of these patients had external fixators that included the foot in the neutral position. Conclusion: The incidence of CS for Schatzker type VI (18%) and medial plateau fracture-dislocations (53%) is high. When compared with the Schatzker type VI injuries, our data suggest that medial plateau fracture-dislocations may be at increased risk of developing CS after placement of spanning external fixation. We recommend careful monitoring of Schatzker type VI fractures and especially medial plateau fracture-dislocations after placement of spanning external fixators.Keywords
This publication has 15 references indexed in Scilit:
- The Effect of Knee-Spanning External Fixation on Compartment Pressures in the LegJournal of Orthopaedic Trauma, 2008
- Medial Tibial Plateau Fractures: a New Classification SystemJournal of Trauma: Injury, Infection & Critical Care, 2007
- Baseline Compartment Pressure Measurements in Isolated Lower Extremity Fractures without Clinical Compartment Syndrome2006
- Staged Management of High-Energy Proximal Tibia Fractures (OTA Types 41)Journal of Orthopaedic Trauma, 2005
- Compartment Pressures During Nonreamed Tibial Nailing without TractionJournal of Orthopaedic Trauma, 1997
- COMPARTMENT MONITORING IN TIBIAL FRACTURESThe Journal of Bone and Joint Surgery. British volume, 1996
- Tibial Plateau FracturesClinical Orthopaedics and Related Research, 1993
- Compartmental pressure changes during calcaneal traction in tibial fracturesThe Journal of Bone and Joint Surgery. British volume, 1982
- The Pathophysiology of the Anterior Tibial Compartmental SyndromeClinical Orthopaedics and Related Research, 1975
- Tissue Pressure Measurements as a Determinant for the Need of FasciotomyClinical Orthopaedics and Related Research, 1975