Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging
Authors:
- Kumar SharmaKumar Sharma
- Christopher R. AndertonCAChristopher R. Anderton
- KPMP ConsortiumKCKPMP Consortium
- 6 February 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (3) , 508-516
Abstract
Automated spraying devices have become ubiquitous in laboratories employing matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time-consuming and can lead to overall nonoptimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirty-two combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 T Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal delocalization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other matrix application approaches and MALDI-MSI analyses of other molecular classes and tissue types.Keywords
Funding Information
- National Institute of Diabetes and Digestive and Kidney Diseases (1UG3DK114920-01)
- H2020 Research Infrastructures (777222)
- H2020 Health (634402)
- H2020 European Research Council (773089)
This publication has 26 references indexed in Scilit:
- Development and evaluation of matrix application techniques for high throughput mass spectrometry imaging of tissues in the clinicClinical Mass Spectrometry, 2019
- Observed metabolic asymmetry within soybean root nodules reflects unexpected complexity in rhizobacteria-legume metabolite exchangeThe ISME Journal, 2018
- Methodologies for the airbrush application of MALDI matricesEuropean Journal of Mass Spectrometry, 2018
- Multimodal MSI in Conjunction with Broad Coverage Spatially Resolved MS2 Increases Confidence in Both Molecular Identification and LocalizationAnalytical Chemistry, 2017
- A one‐step matrix application method for MALDI mass spectrometry imaging of bacterial colony biofilmsJournal of Mass Spectrometry, 2016
- Optimization and Comparison of Multiple MALDI Matrix Application Methods for Small Molecule Mass Spectrometric ImagingAnalytical Chemistry, 2014
- New insights into the structural and spatial variability of cell-wall polysaccharides during wheat grain development, as revealed through MALDI mass spectrometry imagingJournal of Experimental Botany, 2014
- Mass Spectrometric Imaging for Biomedical Tissue AnalysisChemical Reviews, 2010
- Sublimation as a method of matrix application for mass spectrometric imagingJournal of the American Society for Mass Spectrometry, 2007
- Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MSAnalytical Chemistry, 1997