Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil
Open Access
- 1 September 2010
- journal article
- Published by FapUNIFESP (SciELO) in Arquivos de Gastroenterologia
- Vol. 47 (3) , 219-224
Abstract
CONTEXT: The endoscopic procedure safety depends on the use of an adequately reprocessed device which quality is related to each of its operational steps. OBJECTIVE: To characterize the reprocessing of endoscopes using glutaraldehyde in endoscopy services METHODS: Study was conducted by observing the reprocessing of 60 endoscopes from 20 medical practices of the municipality of Goiânia, GO, central area of Brazil. RESULTS: This study showed failure in all reprocessing steps. The pre-washing was performed in 24 (40.0%) of the endoscope. In the cleaning steps, was identify the improper use of enzymatic detergent, and in 27 (45.0%) cases, the brushing of internal channels was not performed. All 60 endoscopes were submitted to this disinfectant. However, for 33 (55.0%) of the cases the internal channels was not filled. The total immersion of endoscope in the glutaraldehyde was not performed in 39 (65.0%) cases. The recommended minimum total immersion time for exposure to 2% glutaraldehyde solution was followed only for 12 (20.0%) endoscopes. There was no filter for water treatment used in the rinse of most endoscopes 54 (90.0%) and to dry the internal channels only 6 (10.0%) of them used compressed air. Adequate storing conditions were identified. CONCLUSION: Considering the particularities of the endoscope and its reprocessing, it is imperative to establish protocols to ensure the quality of the disinfection and the prevention of cross-contamination.Keywords
This publication has 15 references indexed in Scilit:
- Endoscopy-related infection: relic of the past?Current Opinion in Infectious Diseases, 2008
- A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failureAmerican Journal of Infection Control, 2006
- Análise microbiológica de gastroscópios descontaminados em aparelho Cleantop WM-1 por uso de água eletrolítica ácidaArquivos de Gastroenterologia, 2005
- Surface fixation of dried blood by glutaraldehyde and peracetic acidJournal of Hospital Infection, 2004
- The importance of cleaning for the overall results of processing endoscopesJournal of Hospital Infection, 2004
- Reprocessing endoscopes: United States perspectiveJournal of Hospital Infection, 2004
- Water as a Reservoir of Nosocomial PathogensInfection Control & Hospital Epidemiology, 1997
- Patient-to-Patient Transmission of Hepatitis C Virus during ColonoscopyNew England Journal of Medicine, 1997
- Transmission of Infection by Gastrointestinal Endoscopy and BronchoscopyAnnals of Internal Medicine, 1993
- Transmission Of Infection By Gastrointestinal EndoscopyGastrointestinal Endoscopy, 1993