Biostimulatory Effects of Low-Intensity Pulsed Ultrasound on Rate of Orthodontic Tooth Movement and Associated Pain, Applied at 3-Week Intervals: A Split-Mouth Study
Open Access
- 5 May 2021
- journal article
- research article
- Published by Hindawi Limited in Pain Research and Management
- Vol. 2021, 1-6
Abstract
Objective. Low-intensity pulsed ultrasound (LIPUS) is a noninvasive modality to stimulate bone remodeling (BR) and the healing of hard and soft tissues. This research evaluates the biostimulatory effect of LIPUS on the rate of orthodontic tooth movement (OTM) and associated pain, when applied at 3-week intervals. Methods. Twenty-two patients (11 males and 11 females; mean age 19.18 ± 2.00 years) having Angle’s Class II division 1 malocclusion needing bilateral extractions of maxillary first bicuspids were recruited for this split-mouth randomized clinical trial. After the initial stage of alignment and leveling with contemporary edgewise MBT (McLaughlin–Bennett–Trevisi) prescription brackets (Ortho Organizers, Carlsbad, Calif) of 22 mil, followed by extractions of premolars bilaterally, 6 mm nickel-titanium spring was used to retract the canines separately by applying 150 g force on 0.019 × 0.025-in stainless steel working archwires. LIPUS (1.1 MHz frequency and 30 mW/cm2 intensity output) was applied for 20 minutes extraorally and reapplied after 3 weeks for 2 more successive visits over the root of maxillary canine on the experimental side whereas the other side was placebo. A numerical rating scale- (NRS-) based questionnaire was given to the patients on each visit to record their weekly pain experience. Impressions were also made at each visit before the application of LIPUS (T1, T2, and T3). Models were scanned with a CAD/CAM scanner (Planmeca, Helsinki, Finland). Mann–Whitney U test was applied for comparison of canine movement and pain intensity between both the groups. Results. No significant difference in the rate of canine movement was found among the experimental (0.90 mm ± 0.33 mm) and placebo groups (0.81 mm ± 0.32 mm). There was no difference in pain reduction between experimental and placebo groups ( ). Conclusion. Single-dose application of LIPUS at 3-week intervals is ineffective in stimulating the OTM and reducing associated treatment pain.Keywords
This publication has 34 references indexed in Scilit:
- Low-Intensity Pulsed Ultrasound Accelerates Tooth Movement via Activation of the BMP-2 Signaling PathwayPLOS ONE, 2013
- Current Status of Low Intensity Pulsed Ultrasound for Dental PurposesThe Open Dentistry Journal, 2012
- The effect of low intensity pulsed ultrasound in a 3D ex vivo orthodontic modelJournal of Dentistry, 2011
- Focal Adhesion Kinase Is Important for Fluid Shear Stress-Induced Mechanotransduction in OsteoblastsJournal of Bone and Mineral Research, 2009
- Application of ultrasound in periodontics: Part IIJournal of Indian Society of Periodontology, 2008
- Low‐intensity pulsed ultrasound and nonsteroidal anti‐inflammatory drugs have opposing effects during stress fracture repairJournal of Orthopaedic Research, 2007
- Optimal compressive force induces bone formation via increasing bone morphogenetic proteins production and decreasing their antagonists production by Saos-2 cellsLife Sciences, 2006
- Bone morphogenetic protein 4: Potential regulator of shear stress-induced graft neointimal atrophyJournal of Vascular Surgery, 2006
- Repair of orthodontically induced root resorption by ultrasound in humansAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- Interleukin 1 beta and prostaglandin E are involved in the response of periodontal cells to mechanical stress in vivo and in vitroAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1991